Research article · 14 Aug 2025
Research articlePublished 4 Aug 2026
Frequency-Domain Weak-Signal Analysis for Bias-Controlled Medical Response Assessment
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Context: Weak-signal instrumentation proposed for medical response assessment re-quires clear separation between descriptive signal changes, subjective user response, and therapeutic efficacy claims. Objective: To evaluate whether a document-informed custom signal acquisition device produces reproducible frequency-domain differences across ambient, blank control, and labeled test-sample recordings, and to frame a bias-controlled path for pilot user feedback. Methods: Sixteen-bit binary recordings were processed using bias removal, non-overlapping 2048-sample framing, Hann-windowed Fourier analysis, perframe median normalization, difference spectra, and per-bin effect-size estimation. A ten-participant anonymous, non-clinical feasibility feedback summary was reported descriptively. Results: Ambient-air comparisons showed setup-dependent narrowband changes near 30–33 kHz. Blank-control versus test-sample comparisons showed repeated peaks at normalized frequencies near 0.095, 0.119, 0.167, 0.238, 0.333, and 0.489 cycles/sample, with typical shifts of 6–8 dB and within-recording Cohen’s d around 1.0–1.35. The test sample-A versus test-sample-B comparison was smaller, with a maximum shift of about 2.18 dB and |d| ≤ 0.50. Seven of ten participants favored the signal-conditioned eyedrop sample. Conclusions: The findings support a reproducible exploratory signal-analysis work-flow and preliminary anonymous feasibility feedback. They should not be interpreted as validation of therapeutic efficacy.
Keywords
Subjects
Physics & AstronomyAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
More from this journal
The newest in Journal of Medical Physics and Applied Sciences.
Commentary · 16 May 2025
AI-Based Image Segmentation Tools for Medical Applications
Commentary · 16 May 2025
FLASH Radiotherapy for Cancer Treatment: A Revolutionary Approach
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Medical Physics and Applied Sciences
- SubjectPhysics & Astronomy
- BylineArticles whose byline prints “Jui-Hung Lu”
- BylineArticles whose byline prints “Hung-Chiang Cheng”
