A dc cylindrical magnetron sputtering device is designed and its characteristics are studied. The device consists of two copper cylinders with 1.5 and 5 cm in radius and 20 cm in length. A magnetic coil mounted around the outer cylinder generates an axial magnetic field up to 550 G. The effect of different magnetic field on the ionization rate of the discharge is observed. It is shown that the electrical behavior of the discharge strongly depends on the values of the magnetic field and shows an optimum value at which the power absorbed by the plasma is maximum. The effect of different pressure on the ionization rate is also studied and the results are reported.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Similar by topic

More from this journal

The newest in Archives of Applied Science Research.

All its articles

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalArchives of Applied Science Research
  • SubjectPhysics & Astronomy
  • BylineArticles whose byline prints “Jahangir Payamara”
  • BylineArticles whose byline prints “Kiommrs Yasserian”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels