package (eLED), are used to illuminate the breast tissue. A linear charge coupled device (CCD) measures the intensity of the scattered photons at different radial destinations from the illumination source…
Halosulfuron methyl) in pond water samples using dispersive liquid-liquid micro extraction (DLLME) technique coupled with HPLC-UV was developed. The significant factors in dispersive liquid-liquid microextraction such…
instantaneous heat collection efficiency was estimated as 51.5% and the estimated mean heat loss coefficient was 3.84 W/m2 0C. The mean τα product of the system is estimated ... necessary hot water for the generation of…
study was carried out to determine the genetic variability, correlation and path coefficient analysis of lint yield and component characters. The experimental material comprised 122 Bt cotton hybrids of various…
sensitive fluorescence determination of KP from these complex samples were carried out by coupling an ion chromatograph with a fluorescence detector (IC-FLD). The sorbent was prepared by a simple ... concentration range…
MoPH data base. The inequalities and distribution of the workforce were estimated using Gini coefficient and Lorenz curve and linear regression was used to determine the relation between health personnel ... less than…
flow rate of N2 , followed by detection of the Mie scattering using a charged coupling device (CCD) system. Parameters having strong influence during following scattering of the aerosols during their ... between 10.0 -…
using the Unscrambler software (X 10.3, CAMO Software Inc., Trondheim, Norway). The coefficients of determination (Rc2 for calibration and Rp2 for prediction) and root mean square error (RMSEC for calibration…
Background: Male infertility accounts for a main portion of mortalities among couples and not only has economic and social consequences but it also induces psychological and consequently social problems ... variables…
Objective: In the era of the Covid-19 pandemic coupled with the industrial revolution 4.0, it requires us to be able to adapt by making payments through E-Wallet. Accounting ... Indonesia. The study uses qualitative…
developed by dispersive liquid-liquid microextraction (DLLME) without using disperser solvent followed by inductively coupled plasma atomic emission spectrometry (ICP-AES). One variable at the time method was applied…
developed by dispersive liquid-liquid microextraction (DLLME) without using disperser solvent followed by inductively coupled plasma atomic emission spectrometry (ICP-AES). One variable at the time method was applied…
based on the oxidation of 2,4- dinitrophenyl hydrazine (2,4-DNP) and coupling of the oxidized product with drugs to give intensely colored chromogen. Condensed product of Nateglinide ... second method is 0.32% was…
simple, sensitive, and high throughput liquid chromatographic method coupled with the tandem mass spectrometry method has been developed and validated to quantify rizatriptan in human plasma using rizatriptan…
developed a method based on an Ultra-High Performance Liquid Chromatography (UHPLC) assay coupled to a single Quadrupole mass (QDa) detector. Samples were extracted by Supported Liquid Extraction (SLE). Urines ... this…
study, a novel temperature-controlled liquid phase microextraction (TC-LPME) by in-situ derivatization coupled to gas chromatography-tandem mass spectrometry (GC-MS/MS) for analyzing trace estrogens including estrone…
lactulose sugars. Materials and methods: We used a High Performance Liquid Chromatography (HPLC) system coupled to an ABsciex Q-TRAP 5500 triple quadrupole Mass Spectrometer (MS/MS) with an ABSciex ... above the…
effective nonlinear polarizability of plasmonic metasurfaces has been demonstrated through spin-rotation light coupling. The phase of the nonlinear polarization are often continuously tuned by spatially changing the…
UHPLC) and mass detection. Methods: We developed a method based on an UHPLC assay coupled to a single quadrupole mass (QDa) detector. Urines were pre-treated with 1% formic acid ... method was from 5 μg/l to 1000 μg/l…