internal standard (carbamazepine) were eluted from C18 Zorbax ODS(4.6 x 250mm, USA) column at ambient temperature with a mobile phase consisting of acetonitrile and 20mM potassium dihydrogen phosphate buffer
extraction with chloroform. The chromatographic separation was achieved on Thermo Synchronis C18 analytical column (250 × 4.6 mm i.d., 5 μm) at 218 nm wavelength. The mobile phase comprising of methanol
reversed –phase BDS- C18 (250X4.6 mm id) column were done. Data show that mobile phase containing heptane sulphonate (1.5mM as solvent (A) and mixture of phosphate as buffer
ether, chloroform and acetone using a soxhlet extractor. The chloroform extract was subjected to column chromatography over silica gel using petroleum ether and ethyl acetate as eluents. Three compounds were
glucosidase inhibitory activity. Remarkable inhibitory activity was separated by gel filtration and silica gel column chromatography. Four compounds were isolated from the peelings of Citrus dekopon , and their…
extracts examined RAR binding activity. Remarkable activity was separated over silica gel column chromatography. Yeast two-hybrid assay is bioassay technique to use the recombination yeast which introduced a fusion
were baseline-separated within 5.5 min using a flow rate of 0.4 mL/min. Column temperature was 25°C and samples were kept in autosampler on 4ºC. Mass spectrometry detection
determined. Comparison of retention data with those of a commercial octadecyl silica gel HPLC column reveals that the methylene selectivity of the monolithic capillaries prepared in this study is very
validated reverse phase high performance chromatographic technique. Chromatography was performed on Kromasil RP Column C 18 (150 mmx4.6 mm i.d.5 μm particle size) with mobile phase containing Acetonitrile
method utilizes a Oyster BDS C 18 , 5 μm, 250 mm × 4.6 mm i.d. column, at ambient temperature; optimum mobile phase consisted of methanol:ammonium dihygrogen phosphate buffer
method was validated using an ACQUITY HSS C 18 , 50x2.1 mm, 1.8 μ column with a isocratic mobile phase containing a mixture of 1.36 g of potassium dihydrogenphosphate ... flow rate of the mobile phase was 0.5 mL min -1…
internal standard (IS). The mixtures were separated on a C 18 reversed-phase column with an isocratic mobile phase consisting of 0.1% formic acid in acetonitrile and water
chromatographic analysis can be accomplished by using: i) separate HPLC modes/instruments equipped with columns having different selectivity; ii) multi-dimensional chromatography and iii) mixed-mode chromatography. The…
simultaneous assay of β-artemether and lumefantrine. Three reversed-phase fused-core halo HPLC columns (RP-Amide, C18 and Phenyl-hexyl), all thermostated at 30°C, were evaluated. β-artemether ... injected and…
used as an IS. Chromatographic separation was conducted using an Acclaim RSLC C 18 column with a gradient mobile phase consisting of 0.1% formic acid in distilled water
extract and concentrate the volatile compounds before the compounds being injected onto the GC column. Since GC is a gaseous device and analytes introduced into the GC must
volume further, we demonstrate no drop microextraction (NDME) using the liquid inside a separation column of CE as an acceptor phase. Due to the lack of a hanging drop
HPLC-TEA and HPLC-PHRED etc. Most of these methods require post column derivatization with toxic chemicals, time intensive clean up procedures. Otherwise it is easy to generate false negative ... NDELA) in…
method utilized a pressurized liquid extraction (PLE) followed by an immunoaffinity chromatography (IAC) column cleanup with detection by an enzyme-linked immunosorbent assay (ELISA). The IAC columns were developed…
simultaneously measured in one assay are restricted by the choice of chromatographic column, MS detection time, and ionization polarity. In this study, we report a high-throughput, sensitive, and reproducible
polysaccharides and nucleic acids; 3) have total automation; 4) achieve robustness, e.g. long SPE column lifetime; 5) extract of a broad spectrum of analytes; 6) have high speed and throughput
chromatographic method. The analysis was performed on C 8 (250×4.6 mm, 5 μm) column with a mobile phase consisting of 0.03 M potassium dihydrogen ortho phosphate buffer
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.