Conference abstractPublished 25 Oct 2013
Analysis of coplanar polychlorinated biphenyls (PCBs) using immunoaffinity chromatography cleanup with immunoassay detection
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
High analytical costs and uncertainties in the assessment of human exposures to environmental contaminants are concerns expressed by risk assessors. Environmental and biological monitoring studies require cost-effective, high sample capacity methods to determine exposure pathways and minimize risk. Bioanalytical methods, such as immunoassays, have been shown to fulfill these monitoring needs for several target analytes and matrices. Polychlorinated biphenyls (PCBs) are pollutants of environmental and human health concern. We developed a tandem bioanalytical method for the cleanup and determination of coplanar PCBs in soil and sediment samples. The method utilized a pressurized liquid extraction (PLE) followed by an immunoaffinity chromatography (IAC) column cleanup with detection by an enzyme-linked immunosorbent assay (ELISA). The IAC columns were developed using a co-planar PCB specific antibody. Column conditions including support material, loading capacity, antibody binding, and elution solvents were optimized. The IAC column was compared with other sample preparations used for PCBs (acid wash, multi-step cleanup) and was shown to effectively remove interferences from the environmental samples. The columns could be reused more than 20 times without a loss in performance. The ELISA was calibrated against PCB-126 and provided a single measurement representing a PCB-126 equivalent value for the 12 coplanar PCBs. The ELISA was compared to a gas chromatography/mass spectrometry (GC/MS) procedure that provided a summation of the co-planar PCBs present. Quantitative recoveries of 84-130% of PCB-126 were obtained in fortified samples using the PLE/ IAC/ELISA method. The ELISA-derived PCB-126 equivalent values and the GC/MS summation data were highly correlated for all the samples with a correlation coefficient of 0.99.
Ask about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Analytical & Bioanalytical Techniques
- SubjectBiochemistry & Biotechnology
- SubjectChemistry
- BylineArticles whose byline prints “Jeanette M. Van Emon”