First factor was associated with the variation of pH. The second factor was acetonitrile gradient (ACN) in the mobile phase. As pH, acetonitrile modification produced a important modification in terms ... effects of the…
Water Symmetry C18 (150 mm × 4.6 mm) 5 µm column particle size and a gradient elution method. The mobile phase A contains a mixture of 0.02 M KH2PO4 ... flow rate of the mobile phase was 0.8 ml/min with a column…
gradient reversed phase high performance liquid chromatography (RP-HPLC) method has been developed and validated for the determination for eight related substances of Dabigatran Etexilate Mesylate. The successful…
arising and annihilating continuously. It is the Bose-Einstein condensate existing at super low temperatures of the cosmic space. OK, let it be so. Then a motion of this cold ... viscous fluid. We need to modify this…
this research an expertmodel based on artificial neural network was used to estimate temperature distribution along an annular fixed bed reactorwhich has been used in the Oxidative Coupling of Methane ... tray…
Reference Standard as well as in marketed formulation. The chromatographic separation was achieved with gradient elution by using Waters X terra MS (C18, 250 mm×4.6mm, 5.0µm column ... flow rate of 1.0 mL/min and Column…
phosphate (0.05-156 mg/L), nitrates (0.02-1.99 mg/L) and temperature (24.34-25.12oC), while pH (7.75 to 7.29) and dissolved oxygen (5.62-2.38 mg/L) were lowered. There ... respectively, and they decreased along the…
modified Becke–Johnson generalized gradient approximation (nmBJ-GGA), and unmodified Becke–Johnson generalized gradient approximation (umBJ-GGA) were used. Our results on band structure indicate that the cubic and…
called dense dual-phase membranes have shown very interestingly CO2 separation properties at high temperatures. This kind of membrane systems is produced by a porous solid support infiltrated with molten ... carbonate…
initial stages and decreased in the later stages due to the decrease in concentration gradient with time and equilibrium adsorption was established beyond 120 min. The adsorption capacity increased drastically…
initial stages and decreased in the later stages due to the decrease in concentration gradient with time and equilibrium adsorption was established beyond 120 min. The adsorption capacity increased drastically…
different factors. The effect of climatic changes in the area, especially increasing temperature and decreasing rainfalls were clear noticed, in addition, human impacts such as over grazing, agricultural expansion…
Heusler compounds gained considerable attention in the recent past due to their high Curie temperature, high spin polarization and tunable electronic structure with possible applications in spintronics. They have…
Heusler compounds gained considerable attention in the recent past due to their high Curie temperature, high spin polarization and tunable electronic structure with possible applications in spintronics. They have…
branched architectures promote the crystallization behavior of each constituent significantly. Both crystallinity and melting temperature greatly raised from linear to comb-shaped copolymers. Compared to linear-comb…
shape memory alloy Fe70Pd30; (i) hybrid mechanism of chain reaction events; applied magnetic field gradient, magnetic force, stress-induced martensite phase transformation of Fe70Pd30 from stiff austenite to soft…
tetramethyl-uronium-hexafluoro-phosphate) and HOBt (N-Hydroxybenzotriazole) for 2h at room temperature under constant shaking. Deprotection was carried out using 20% piperidine for 20 min under constant shaking. Between…
shape memory alloy Fe70Pd30: (1) Hybrid mechanism of chain reaction events; applied magnetic field gradient, magnetic force, stress-induced martensite phase transformation of Fe70Pd30 from stiff austenite to soft…
ammonia from it slows down. Depending on the composition of the manure, the temperature environment, the duration of exposure to the biopreparat, the emission is reduced to 22%. The greatest ... crust on the surface…
experimental system in Comsol 5.2 is allowed to verify the observed fluid flow and temperature patterns. Magnetomigration is the first step to magnetic separation of rare earth ions. Recent Publications ... Segregation…
climate can be estimated as hemi-continental. The phytoindication evaluation reveals that the temperature of the coldest month is –4,8 ° C. The light mode is heliophyte friendly. The synphytoindication ... response of…
uses Purosphere STAR RP 18-endcapped (250×4 mm, 3 μm) column and a gradient elution with a flow of 1 ml/min. Mobile phase buffer was prepared by adding ... eluted compounds were monitored at 226 nm and 240 nm. The…
pressure liquid extraction on a solid matrix, working on the principle of a pressure gradient created among the core of the matrix and the outer bulk. The main advantages consist ... defined amount of karkadè oil were…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.