Scholars Central

Conference abstractPublished 2018

Identification of degradation products of fensipiride hydrichloride in stress degradation media

Authors: Ioana Caba, Marius Niculaua, Luminița Agoroaei, Bogdan Cioroiu

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Fenspiride hydrochloride is used on chronic inflammatory diseases. Most used formulations are liquid oral solutions. Fenspiride hydrochloride (FNS) enables a series of degradation products along with fenspiride N-oxide (FNO) and 1-phenylethyl- 4-hydroxy-4-aminomethyl piperidine hydrochloride (PHAP). The method of determination includes a mobile phase consisted in a quaternary mixture formed of solution pH 4.5, acetonitrile, methanol and solution of pH 2.9. Workflow was 1.5 mL min-1 and the elution was a double gradient in organic solvent and from solution with pH 4.5 to 2.9. Linearity interval ranged between 0.5 μg mL-1 to 2 μg mL-1 and correlation coefficients are minimum 0.999. Recovery factors were between 100.47% and 103.17% and the limits of qualification were between 0.19 and 0.332 μg/ ml. intra-day precision was of maximum 4.08% for FNS and 2.65% for PHAP. This double gradient of mobile phase produced a good specificity in relation with the degradation products of fenspiride hydrochloride and other constituents of the liquid oral solution. Forced degradation studies revealed another related substances and degradation studies confirmed in mass balance analysis. Degradation products were confirmed in acidic, basic and oxidation media. A full factorial design was used for the optimization of model. Previous mentioned parameters were considered as started conditions. The design had a number of 2 factors, 4 runs and 1 block. The factors were coded as -1 and +1. First factor was associated with the variation of pH. The second factor was acetonitrile gradient (ACN) in the mobile phase. As pH, acetonitrile modification produced a important modification in terms of resolution and separation efficiency. The full factorial design used a multi-linear regression model and evaluated the final response as a function of constant of experimental response and the estimated effects of the factors. Most important parameters which affected the method specificity were pH, temperature and organic components.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalInternational Journal of Drug Development and Research
  • SubjectPharmaceutical Sciences
  • BylineArticles whose byline prints “Ioana Caba”
  • BylineArticles whose byline prints “Marius Niculaua”
  • BylineArticles whose byline prints “Luminița Agoroaei”
  • BylineArticles whose byline prints “Bogdan Cioroiu”