solvent methanol (r2=0.999). The methods were validated according to ICH guidelines for accuracy, precision, sensitivity and ruggedness. There was no significant difference between performance of the proposed methods…
present study was to develop and validate reverse phase highperformance liquid chromatography (RP-HPLC) method for the estimation of Ritonavir. The RP-HPLC separation was achieved on JASCO HPLC system
spot for MONT and 4000 to 8000ng/ spot for THEO. The method was validated for accuracy, precision, specificity and robustness. The limit of detection and quantitation were ... spot for MONT and THEO respectively. The…
this study, an attempt was made to describe and validate a liquid chromatography coupled with tandem mass spectrometry method for the quantification of methoxsalen, an antipsoriatic agent in human EDTA
bench during 12 h and post preparative stability study. The proposed method was validated statistically by performing recovery study for determination of ciprofloxacin and ornidazole in human plasma. Conclusion
purpose of the investigation was to develop a new RP-HPLC Method for estimation of Abiraterone in pharmaceutical dosage forms. Chromatography was carried out on an Symmetry shield ... detection was carried out using a…
specific, sensitive, and rapid stability-indicating chromatographic method has been developed, optimized and validated for simultaneous determination of ramipril (RAM), atorvastatin (ATV) and aspirin (ASP) in their…
spiked onto representative surfaces, which are dried, sampled and analyzed using the validated HPLC method. Additionally, the robustness of sampling procedures was assessed. For swab sampling the surface (sampling area…
HPLC technique was developed and validated for concurrent assessment of cabotegravir and rilpivirine in pure and medicinal dose form. Materials and methods: The analyte separation was achieved by Waters
specificity when developing stability indicating methods, especially when little is known about potential degradation products. Force degradation studies are helpful in development and validation of stabilityindicating…
simple capillary gas chromatography method using a flame ionization detector has been developed and validated for the quantitative determination of trace analysis of 2, 2’-Azobis-Iso-Butyro-Nitrile (AIBN ... time was 25…
λmax) at 237 nm and 296 nm with methanol as the solvent. The method was validated as per the International Conference on Harmonization (ICHQ2R1) guidelines. Drugs followed the linearity ... correlation coefficient (r2)…
eluted at retention time of 2.4, 2.8 and 4.5 min (± 0.5). The proposed method was validated as per ICH guidelines. The correlation coefficient (R2) was found ... found to be novel, simple, accurate and robust and the…
respectively. Conclusion: The developed method was validated and applied to the bulk drug and formulation of Bempadoic Acid and Ezetimibe. All the results obtained with this method were accurate