pressure is extended to study the compression of solids at constant temperature. Two slightly different formulations are used and a modified form is proposed on an empirical basis. The Shanker ... study. It is found…
integrated methodology for detection, location and severity of damage in a plate like structure. Finite element analysis is used for simulating the crack model. In the first approach, piezoelectric patches ... structure…
aortic valve, with each layer being collagen, collagen-CS, and collagen-elastin respectively. The different mechanical properties of each layer introduced a desirable bending anisotropy to the scaffold, which mimicked…
used microfibers combined with nanoparticles to improve mechanical properties of materials. Various nanoparticles with different shapes and sizes are used to improve the mechanical properties of resin-based matrix…
This paper demonstrates the use of two different numerical simulation methods for predicting the penetration and deceleration over time of a high velocity projectile ... concrete target with a confined pressure of 39…
compounds compress and shears intensely, causing die-swelling phenomena on die exit. There are different kinds of swelling during the extrusion process. One is a recoil mechanism ... required die design to obtain the…
reviewed and shown to be compromised by experimental inconsistencies or by the presence of finite chain polyenes. This situation has been reviewed in an open paper. A method for preparation ... separation of 0.82 nm in…
temperatures were considered for finite element analysis and their effects on end-plate moment connection were discussed. It has been found that with the increase of temperature, end plate thickness ... stiffness of end…
rotational symmetric structure. The time-dependent heat conduction model is solved using the finite element method. In order to see how serious heat accumulation is, taken as an example ... first turn. The temperature…
absorption of energy takes place during progressive folding process of the tube. Tubes with different shapes are studied by many researchers. In this research work, a rectangular steel tube ... determined by using…
mechanical and physical properties, the behavior of FRP reinforced concrete (RC) members is significantly different to that of traditional steel RC. This paper presents the results and discussion ... beams under…
patients obtained from DICOM by image segmentation methods. The geometry meshed by finite element models. The blood flow is recreated by defining boundary conditions of patients in the clinical results ... years old…
patients obtained from DICOM by image segmentation methods. The geometry meshed by finite element models. The blood flow is recreated by defining boundary conditions of patients in the clinical results ... years old…
bending modulus (21.9±4.1 kPa with curvature VS 39.3±3.6 kPa against curvature). A finite element approach (ANSYS) was used here to simulate the three-point bending tests ... were performed, and showed that the bi-layer…
bending modulus (21.9±4.1 kPa with curvature VS 39.3±3.6 kPa against curvature). A finite element approach (ANSYS) was used here to simulate the three-point bending tests ... were performed, and showed that the bi-layer…
bending modulus (21.9±4.1 kPa with curvature VS 39.3±3.6 kPa against curvature). A finite element approach (ANSYS) was used here to simulate the three-point bending tests ... were performed, and showed that the bi-layer…
century, universities and students alike have called out for a wholeperson education based integrating different academic disciplines. The integrative holistic education paradigm resembles and parallels the integration…
universities and students alike have called out for a whole-person education based integrating different academic disciplines. The integrative holistic education paradigm resembles and parallels the integration of…
operate in voltage and current mode under two time points following implantation. Methods: The finite element method was used to model Lead 3389 (Medtronic) and 6148 (St Jude) with homogenous ... impedance mimicked the…
laser welding process for thin plate of the steel. Several mitigation methods, including elastic finite analysis, inherent strain theory were used to predict and control the distortion which produced ... effect of…
tuning parameter step, which turns out to be the bottleneck for efficient implementations. Although different variations and GPU-based implementations are published monthly, it is not straightforward to use them…
determine the best implant position for lowest value of micromotion. In this study, finite element model of femur was created from 3D CT scan data using ImageSim software from VOLMO ... exporting volume mesh. This…
braided yarns (cBYs) were fabricated on a 32 bobbin braiding machine 1(a)) with different feed yarn ratios (7:1 for cBRS type A, 3:1 for cBRS type ... parallel compression tester.The stent stress distribution and…
induced crossover from itinerant to localized magnetism observed for isolated Fe impurities embedded in different structural polymorphs of silver. Physical Review B. 94:184431. 4. S Chattopadhyay ... Physics…
risk of post operative fracture is currently unknown. We developed three three-dimensional (3D) finite element models using computerised tomography (CT) scan data for a hip with cam-type impingement ... femoral…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.