Optimisation of implant position in cemented femur in total hip replacement
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Total hip replacement (THR) is one of the most common and effective surgical procedures performed worldwide with the purpose of improving the quality of life of patients suffering from hip disorders. There are two major types of artificial hip replacements: Cemented and uncemented. This paper presents finite element approach to measure micromotion along the stem / cement and cement/ bone interface. A response surface model (RSM) was created and used to determine the best implant position for lowest value of micromotion. In this study, finite element model of femur was created from 3D CT scan data using ImageSim software from VOLMO Ltd. (UK). Surface model of femur in STL format was exported into CAE environment (TSV Pre) where femur resection, implant positioning and alignment were done. The final assembled model of bone, cement and implant was used as the base model for creating new models. The loading and boundary condition have been applied for walking condition. Model Generation using Script: Java scripting functionality within the tool provided a robust environment for automatically rotating the implant to a new angle, exporting STL, Volume meshing, applying load boundary condition and finally exporting volume mesh. This technique provided an efficient approach for generating new models with different implant positions in the femur bone. Around 25 models were generated in less than six hours. These models were then simulated in DYNAMIS solver available internally in the environment. Results: The shear strain distribution and micro motion on the femoral bone with fitted implant for walking loading condition was calculated. The regions studied were the stem, cement and bone in the proximal level. The maximum values were observed in shear strain γyz along the stem /cement interface below the stem neck. High values were also observed in shear strain γzx in the lower side of stem. Shear strain γyz & γzx can be reasonably considered to be the stimulus of the slip initiation and micromotion at the cement stem interface. Maximum micromotion observed was 75 micron along the γyz direction. Our initial results also showed that there is more than one implant position where micromotion reaches a minimum. The results obtained from the study demonstrated the potential applications of the tool for predicting the best and worst positions for an implant. The response surface methodology is useful for providing insights into the sensitivity of micromotion to positioning.
Subjects
OrthopaedicsAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
More from this journal
The newest in Orthopedic & Muscular System: Current Research.
Perspective · 21 Apr 2025
Comprehensive Overview of Arthrodesis: Indications, Procedure and Recovery Process
Short communication · 14 Mar 2025
Translational Research in Musculoskeletal Regeneration and Repair
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalOrthopedic & Muscular System: Current Research
- SubjectOrthopaedics
- BylineArticles whose byline prints “Ash Harkara”
- BylineArticles whose byline prints “Shani Jain”
- BylineArticles whose byline prints “Mayank Taygi”
- BylineArticles whose byline prints “Tasos Iakovidis”
- BylineArticles whose byline prints “Christos Theodosiou”