linearity, precision, accuracy, stability, specificity and ruggedness, as per ICH norms. Calibration graphs are linear in the concentration range of 5-30 μg/ml, while the correlation coefficient ... determination of…
validated according to the International Conference on Harmonization (ICH) guidelines. Calibration curves were linear within the wide range of 10-50 μg/mL for all drugs, with a determination coefficient ... between %…
focused on utilizing various methodologies to attain higher accuracy and precision in the chromatography analysis. • Reducing the Size: Breaking the stronger aggregation is the easier way to reduce the size…
long-tailed histogram fitted by the PDE. PDE is a novel algorithm used to linearly map long-tailed histograms onto a given category of functions on the Planckian Plane ... treatment mRNA levels for longer surviving…
used to identify the determinants for farmer’s decisions on adaptation measures, while linear regression and Pearson’s correlation were used to identify relationships and effects of climatic variables ... while 85%…
variable viscosity and Prandtl number. The analysis includes the effect of suction/blowing and heat generation/ absorption. Design/methodology/approach: The non-linear partial differential equation governing the flow
principally based on the empirical solutions. These equations have been developed to establish a linear or nonlinear relationship between collapse pressure and important parameters causing a casing to collapse. From…
using ethanol as solvent. The method was validated using parameters as linearity, accuracy and precision, limit of detection and limit of quantitation as per ICH guidelines. The concentration of Gallic ... obeyed the…
International Conference on Harmonization (ICH) guidelines and validated using the acceptance criteria of linearity, range, accuracy, precision, limit of detection (LOD), limit of quantitation (LOQ), and stability. From…
greater gains in profitability; and (3) though the hypothesized linear relationship between advertising and profitability is not confirmed, further analysis indicates a U-shaped curvilinearity between the two…
rates andco-morbidity rates. Exploratory data analysis was then performed to attempt to find trends. Afterwards, we fit our data to a linear regression model to identify the factors that ... predictor of COVID mortality…
association between LTL and indexes of LV diastolic function were evaluated using correlation analysis, linear regression analysis and analysis of variance (ANOVA) after adjusting for possible confounders. Mean values
high selectivity of antibody. Magnetic immunoassay using multifunctional nanoparticles has great potential in biochemical analysis. This presentation would show several biochemical analyses using bio-functional…
emotional intelligence "Bar-On Emotional Intelligence Scale Child and Adolescent Form". Pearson correlational analysis and multiple linear regression were conducted to reveal the relationships between study variables…
injection volume was 10 µL and UV detection was kept at 205 nm. Linearity was in the range of 0.5-100 µg/mL for amoxicillin ... such drugs in their pharmaceutical formulation and can be applied for routine quality…
Niño anomalies on the summer rainfall of these regions by grid data analysis with Open-Grads climate data display to understand the impacts of the IOD/Niño anomalies on Myanmar ... point is around values of +/- 0.3 and…
Artificial neural network have proven to be an effective tool in the analysis of non-linear data by establishing a relationship between experimental and predicted data through historical data records
statistically differences were found in the histological characteristics between the two groups. Univariate analysis showed a positive correlation between serum C3 and eGFR ... model, respectively. Furthermore, curve…
ligand concentration, 0.44 mol L-1 and pH= 8. The linear dynamic range of analysis was 3.0-100.0 μg L-1 with correlation coefficient of r2> 0.9998. The method detection
coupled positive and negative feedback loops). Finally, we review the procedures of linear stability analysis, which allow one to determine whether a given ODE model and a particular
percentages of residual biofilm were measured using image analysis software. The data were analysed using Kruskal-Wallis test and generalised linear mixed model. Results: The greatest biofilm removal was associated
feature extraction. The most commonly used technique for input space reduction is Principal Component Analysis (PCA) while two of the most commonly used data normalization approaches include ... gradient vector and the…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.