Scholars Central

Conference abstractPublished 15 Mar 2021

Developing a start of art for improvising the chromotography analysis of suspension sample for higher precison and accuracy

Authors: Balaji APB, Killi Ganesh

Ecoysus Life Science, India

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

A recent development in the formulation science has come up with the novel formulation designed to serve the purpose. The formulations are aimed at a high loading of the active compound, lower viscosity, easier dispersion, and higher stability. Among several formulations, the suspension formulation is quite challenging for the chromatography analysis as they are not true solutions. The suspension is the dispersion of solid particles in the aqueous or non-aqueous medium. A major issue that arises in the suspension samples is that pipetted sample concentration varies with respect to time and the point of drawing the sample. Hence, the accuracy precision for suspension ranges from 85 – 115 %. Even though common techniques were available like allowing the solution to stand for 30 min upon stirring or separating the suspended particles by centrifugation, it doesn't yield accurate results. In order, the present review focused on utilizing various methodologies to attain higher accuracy and precision in the chromatography analysis. • Reducing the Size: Breaking the stronger aggregation is the easier way to reduce the size of clusters. The stronger aggregation can be avoided by introducing the shear force in the solution, by means of breaking the suspended solids into smaller ones • Altering the surface property: The property of the suspension can be easily altered by utilizing the polymers or surfactants • Preparative directed Analytical LCMS: A technique of analyzing the whole sample in preparative HPLC and diverting the fraction of active compound into Analytical quantification or LCMS • Choosing the quantitation method: The concentration varies with the calibration point and quantitation method used such as the Linearity curve method or Area normalization method. The present review provides insights towards the potential possibilities of reducing the suspension sampling error, thereby improvising the precision and accuracy in the chromatography techniques.

Subjects

Chemistry

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Chromatography & Separation Techniques
  • SubjectChemistry
  • BylineArticles whose byline prints “Balaji APB”
  • BylineArticles whose byline prints “Killi Ganesh”