A High Power Factor DC Drive for Universal Input Voltage Applications
proposes a high power factor DC drive for the speed control of DC motor. In electric power system, load with low power factor draws more current which leads to energy
Articles, journals and conferences in one search. An exact title, DOI or ISSN is listed first.
In the search box: "exact phrase" · -leave out · OR · prefix* · title: author: journal:
proposes a high power factor DC drive for the speed control of DC motor. In electric power system, load with low power factor draws more current which leads to energy
innovatively as i) a load reactive power compensator ii) an interface unit between the grid and renewable energy source, and iii) Voltage regulator. A controller unit is proposed
Power Filter (APF) topology and Buck-Boost circuit topology are realized. Here the nonlinear load considered is a 12 pulse diode bridge rectifier. First, harmonic mitigation and power factor correction ... three phase…
Permanent Magnet Synchronous Generator (PMSG), hybrid energy storage, a dump load and a mains load is considered in this project. The hybrid energy storage consists of battery storage ... employed to provide reactive…
circuits to meet the output regulation requirements for change in load. Loop Feedback is closed by make use of control winding. Input output isolation is met using gate drive transformers
nonlinear load led to the injection of harmonics into the power system. In this paper, the performance of two topologies of shunt hybrid power filters for compensating voltage and current ... control algorithm used in…
state, the energy is transferred from the transformer to the output load and the output capacitor. By controlling the duty ratio of switch used in the primary of transformer
output pulses from rotor position sensor using Microchip PIC24HJ128GP310 microcontroller. A digital PI controller is also implemented with the proposed speed measurement method in the feedback circuit. The…
presented. The input impedance is controlled by two varactor diodes to compensate for impedance changes with RF input power and dc loading conditions. The RF?dc converter achieved a peak
voltage sag, swell, voltage transient & voltage unbalance. UPQC can supply VAR to the load. DSP based controller is connected to UPQC in order to increase the system performance
power factor and distorting the waveform. An ideal rectifier presents an effective resistive load (Emulated resistance) to the AC power line; hence, if the supplied AC voltage is sinusoidal, then ... unity. The boost…
This paper focuses the design of Bridgeless SEPIC topology having reduced switching
modeling and simulation of renewable energy sources based hybrid power system. To meet the load demands different renewable energy sources with local converters are considered to boost up as well ... required to have…
reliable and low cost. The nonlinear load produces abnormal conditions, such as voltage imbalance, harmonics current and ripple current. The error can be controlled by using PI controller. With
with discontinuous conduction mode and using a PI controller, power factor can be improved with reduction in harmonics. By changing the load using a dc motor, high efficiency with ... usually used for high power…
indirect vector control system uses conventional PI controller in the outer speed loop because of the ease and constancy, unexpected change in load conditions or environmental factors produce overshoot, fluctuation
results of BLDC drive employing conventional PI and PSO based PI controllers is compared and evaluatedunder various load disturbances in the MATLAB/simulink environment
complex interconnected system which comprises of reactive power compensators nearer to the load and are used to operate the power system closer to the limits of stability. Reactive power support ... distribution system…
into operation. At night and during no sunlight periods, the power required by the loads is received from the distribution system while the inverter system only providesreactive power andfilter harmonic ... current…
controllable high-voltage dc bus and middle-voltage output terminals. The high-voltage dc bus can take as the main power for a high-voltage dc load or the front
speed of driving of MCI and mild AD patients and middle aged/older healthy controls are presented in two rural driving simulation environments: High traffic with and without distraction (conversation ... urban driving…
tangles) of sporadic Alzheimer and Down syndrome patients, but not in young non-demented controls. This was the cover story of Science 279, January 9th, 1998. The message is that ... focus on interactions of hypoxia…
revealed a one-component solution with component loadings ranging from 0.82-0.89. Cronbach?s alpha of the ELUS-11 was 0.96. Controlling for age, hours spent in paid employment
that prioritizes the sources in the order they should be connected to the load. The control system reads the load voltage and frequency and determines an error depending
achieving both these objectives by a single stage. This paper presents a PWM control strategy based switched Boost Inverter (SBI) for DC nanogrid applications. Using Switched boost inverter ... risk of damaging the…
For authors and organisers
Find the right journal for your paper and submit your manuscript.