Mass attenuation coefficient and linear attenuation coefficient of gamma rays of photons for Ni in the energy range 360- 1330 keV have been determined experimentally through photon–transmission measurement performed…
Measurements of mass (μ/ρ) and linear (μ) attenuation coefficients of silver in the energy range 0.360Mev to 1.33Mev have been carried out under narrow-collimated-beam method ... with scintillation detector. The values…
Measurements have been made to determine gamma ray attenuation coefficients very accurately by using a narrow-collimated-beam method which effectively excluded corrections due to smallangle and multiple scattering…
essential nutrients to the body needs in small amount to work properly. The attenuation coefficient is an important parameter for characterizing the penetration and diffusion of x-rays and gamma ... using NaI(Tl)…
linear attenuation coefficient (μ), mass attenuation coefficient (μ/Ñ) were calculated for Zn element. The values of gamma ray mass attenuation coefficient were obtained using a NaI (Tl) detector using ... thus…
mass attenuation coefficient of drug was determined at low photon energies ranging from 8 keV to 44 keV using High Purity Germanium (HPGe) detector for the samples of different firms ... Diclogesic, were carried out by…
various thicknesses of absorbers different characteristics about the isotopes can be determined. Linear attenuation coefficient (μ) of gamma rays photons of energy for 0.662, 0.511 and 1.274 MeV in zinc ... geometry…
adulterants like water, urea, lactose powder etc. in milk sample. The linear and mass attenuation coefficient plays an important role in agricultural dairy,food technology, science & technology, medicines and forensics…
adulterants like water, urea, lactose powder etc. in milk sample. The linear and mass attenuation coefficient plays an important role in agricultural dairy, food technology, science & technology, medicines and forensics…
Mass attenuation coefficient for g-ray photons of energy 0.279MeV in Cr, Ni, Cu, and Ag have been determined experimentally through photon-transmission measurements performed under narrow-beam counting ... geometry with…
total attenuation coefficients,σtot, of biological materials such as amino acids have been studied as a function of weight fraction of constituent elements (hydrogen, carbon, oxygen and nitrogen ... observed that in low…
this research, MCNP model for studying mass attenuations coefficients for steel, Red brass, Pearl and Beryl at 661.6, 1173.2 and 1332.5 keV photon energies is investigated. The simulated results ... mass attenuation…
solution of Phenol (C6H6O) studied for different concentrations. Mixture rule for theoretical calculation of attenuation coefficient is developed for the solution; our study explores the validity of the expected…
para-nitro aniline (C6H6O2N2) studied for different concentrations. Mixture rule for theoretical calculation of attenuation coefficient is developed for the solution; our study explores the validity of the expected…
para-nitro aniline (C6H6O2N2) studied for different concentrations. Mixture rule for theoretical calculation of attenuation coefficient is developed for the solution, our study explores the validity of the expected…
total attenuation coefficients, μ/ρ, of some biologically important vitamins containing H, C, N and O have been studied as a function of weight fraction of constituent elements. A considerable
sources. The measured efficiency values are used in this method to find the peak attenuation coefficient for this particular source-to-detector geometry. In addition, the obtaining values were used
Gamma attenuation coefficients of host rocks belonging to Moghra Formation of Eocene era in one of two candidate sites located at the North Western Coast of Egypt in Al-Dabaa ... type, provided that roch sample density…
xBixMo0. 05xO7 - chemical compositions (4x, 0 ≤ x ≤ 0.4 mol%) have been assessed. the ass attenuation coefficient values were theoretically calculated by using XCOM the available online of the XCOM software ... Based on…
energies (59.5, 81.0, 356.5, 661.6, 1173.2 and 1332.5 keV). Appreciable variations are noted for attenuation coefficients by changing the photon energy and the chemical composition of the samples. The numerical…
Measurements of mass (μ/ρ) and linear (μ) attenuation coefficients of Copper in the energy range 10keV to 1500keV have been carried out under narrow-collimated-beam method with ... photon detector. The values of mass…
mass attenuation coefficients, partial interaction and shielding properties of xBi2O3: (60-x) BaO:40B2O3 where 10ï‚£xï‚£50 glass system have been investigated on the basis ... results are in good agreement with…
study, ZnO/Acrylamide composites were considered as gamma and x-ray shielding. The mass attenuation coefficient and half value layer for the bulk of ZnO and various percentages ... MCNP-X) version 2.4.0T was used as a…
Measurements have been made to determine gamma ray attenuation coefficients very accurately by using a narrow-collimated-beam method which effectively excluded corrections due to smallangle and multiple scattering…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.