structural health monitoring. The POF sensor provides a new alternative for monitoring the concrete curing processing since the conventional monitoring techniques have many limitations. This paper briefly presents a…
Self-curing concrete is one of the special concretes in mitigating insufficient curing disorder due to human negligence and paucity of water in arid areas, inaccessibility of structures in difficult ... concrete…
clay is used for internal curing of concrete. The major advantages in internally cured concrete are, the concrete is light weight, free from shrinkage cracks, 3-dimensional curing, and limited ... This study also deals…
hypothesis for this research that the compressive strength of early-age concrete cured by seawater is higher than the one cured by plain water. This research was conducted by using ... concrete cylinders, with 7 days…
were tested for workability and hardened concretes were tested for compressive strength and water absorption at 7, 28 and 90 days of curing in lime solution. The overall results confirmed
rebar. From the tests and study, the compressive strength and water absorption of the concretes cured with fresh water is better performance than those cured with seawater. The concretes mixed
compressive strengths for 0%, 5%, 7.5%, 10% and 15% replacements of RHA concrete when cured with normal water and 5% NaCl solution is investigated. For experimentation process ... studied for 3days, 7days, 28days and…
research interest is to find the compressive strength of this particular concrete under different conditions of curing and consolidation to compare each approach with each other. In this article ... worthwhile to…
radio wave technology (the operating principle is similar to that of microwaves) during the concrete curing process. An accelerating hardening of the concrete will be achieved. The application
incorporation of graphene into the concrete matrix increases the compressive strength of the fully cured concrete by 26. Conclusion & Significance: Our results indicate that the increase in early age compressive
incorporation of graphene into the concrete matrix increases the compressive strength of the fully cured concrete by 26. Conclusion & Significance: Our results indicate that the increase in early age compressive
downsize aggregates showed higher conductivity compared to 12mm downsized aggregates. And as expected cured concrete blocks showed greater conductivity compared to uncured block. Peak Current analysis showed there
downsize aggregates showed higher conductivity compared to 12mm downsized aggregates. And as expected cured concrete blocks showed greater conductivity compared to uncured block. Peak Current analysis showed there
concrete M20, M25 were prepared using potable water for mixing and curing. The same grades of fly ash concrete were once again prepared using potable water for mixing and cured ... curing. Investigation was carried out…
analysis engineering, the physical and mechanical properties of river sand concrete with quarry dust concrete. The selected materials were batched by weight and volume. The water-cement ratio was opted ... concrete…
influence of partial replacement of Portland cement with sugarcane bagasse ash in concrete subjected to different curing environments. Experimental investigation on acid resistance of concrete in mgso4 solution. The…
mixtures were kept constant as those in the control one except water type. Cured mortar and concrete specimens for each mix were tested at 7 days age as strength indication ... days to obtain compressive strength. The…
requirement of the merchandise. Plasticizers are chemical compounds that enable the assembly of concrete with ca. 15% less water content. Superplasticizers allow reduction in water content by 30% or more ... extent of a…
percentages of rice husk ash (0%, 5%, 10% and 20%) on durability aspects of concrete, when exposed to varying degree of aggressive attack due to sulphates, nitrates and chlorides ... from 5% to 20% were cast. After 28…
cement in concrete production. A total of 100 specimens of the GSA/OPC concrete was cured in cubes of 100mm dimension for 7, 14, 21 and 28 days ... standard, a percentage replacement of 10% is suggested for sustainable…
plasticizer. The geo polymer concrete flexural strength beams were cast and pasted with the carbon fibre in tension side by using epoxy resin and cured under atmospheric temperatures. After ... environment plays a major…
This work studies the effect of atmospheric steam curing (by solar energy) on the mechanical strength of concrete for prefabrication constructions. During the early hours of heating, the concrete reaches ... conducted…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.