Search Scholars Central
Articles, journals and conferences in one search. An exact title, DOI or ISSN is listed first.
Advanced searchHide advanced search
In the search box: "exact phrase" · -leave out · OR · prefix* · title: author: journal:
Opinion · 23 Sep 2022 Research article · 2015 Inhibition of the BER Factor APE1 Disrupts Repair of Double-Strand DNA Damage in Cells Treated with Low Dose-Rate, but Not High Dose-Rate XRadiation
APE1-specific inhibitor CRT0044876 (CRT), in tumour cells following exposure to either high dose-rate (HDR) or low dose-rate (LDR) X-irradiation. Materials and Methods: Treatment efficacy was assessed ... dsDNA repair…
Conference abstract · 22 Jun 2015 Dose rate measurement in different granite samples of Bangalore Metropolitan, India
estimation of the exposure from the natural radiation sources. Reported values for effective gamma dose rate for the Bangalore environment varied in the range 90-260 nSvh-1 with mean ... nSvh-1. As the observed dose…
Article · Jul 2021 Evolution of Low-dose-rate Brachytherapy Imaging Equipment in the Prostate.
Short Communication Low dose rate brachytherapy has traditionally been used to treat cancers of the prostate, head and neck, breast, cervical, endometrium, oesophagus, bronchial lesions [1]. Permanent implants have…
Conference abstract · 15 Aug 2016 Role of high dose rate Brachytherapy in early and locally advanced squamous cell carcinoma of oral cavity
Background: The study was intended to assess the effect of high dose rate brachytherapy in early and locally advanced squamous cell carcinoma of oral cavity for local control, toxicity ... lesions in the floor of mouth…
Editorial · 2015 Dose Rate and Dose Painting
Research article · 28 Feb 2025 Comparison of Absorbed Dose Rate in the Healthy Organs by the Mammosite and Contura Applicators in Breast Brachytherapy
Brachytherapy is one of the treatments for breast cancer. In brachytherapy treatment systems, high dose rate sources are used in interstitial implantation. By the late 1960’s, with ... Oxford in 1976 and has been widely…
Research article · 7 Feb 2024 A Hybrid Deep Learning Model for Space Radiation Dose Rate Prediction
prediction of space radiation dose rates holds significant importance for space science research. In this paper, a hybrid neural network-based approach for forecasting space radiation dose rates is proposed
Short communication · 27 Jun 2023 Urethral Dosimetry and Side Effects of Vaginal Cancer High-Dose-Rate Interstitial Brachytherapy
A retrospective chart overview was once carried out that encompassed sufferers who
Commentary · 21 Jun 2023 Originating the New Analytical Exploration of the Dose-Response Curves at Various Dose Rates
Short communication · 23 Feb 2022 Review of Pulsed Reduced Dose Rate Re-irradiation for Recurrent Tumors
Research article · 29 Sep 2021 A Prospective Randomized Study to Compare Clinical Outcome of External Beam Radiotherapy (EBRT) and Sequential High Dose Rate Intracavitary Brachytherapy (HDRICBT) With or Without Concurrent Cisplatin on the Day of ICBT Insertion in Treatment of Locally Advanced Carcinoma CervixD
The study reviews that cervical cancer is among the most commonly diagnosed
Review article · 27 Sep 2021 Emergence of Quality Low-Dose-Rate (LDR) Brachytherapy: Ultimate Radiosurgery for Non-Metastatic Prostate Cancer
author summarizes technique, application and oncological outcome of the high-quality high-dose, Low- Dose-Rate (LDR) branchy therapy that can minimize local recurrence of prostate cancer
Review article · 5 Feb 2021 High dose rate brachytherapy for prostate cancer: rationale, current applications and clinical outcome
High-dose rate brachytherapy (HDR BRT) has been enjoying rapid acceptance as a treatment modality offered to selected prostate cancer patients devoid of risk group, employed either alone ... research areas. This review…
Conference abstract · 31 Jan 2020 Dosimetric analysis in patients of breast cancer treated with image based high dose rate multicatheterinterstitial brachytherapy as a boost following whole breast irradiation
assessment of treatment plans in patients of breast cancer treated with image based high dose rate interstitial brachytherapy as a boost following whole breast irradiation. Materials and methods:Fifteen patients…
Research article · 26 Jul 2019 Evaluation of the Characteristics of Ionization Chambers Used for Commissioning in High Dose Rate Linacs
Introduction: Recently there has been an increased interest in high dose rate free flattening filter (FFF) linear accelerators which are used clinically in most of the advanced radiotherapy techniques such ... results…
Research article · 3 May 2019 Indoor radon and thoron levels and the associated effective dose rate determination at the health centres in the Basrah Governorate-Iraq
Study of indoor radon and thoron has been carried out in the
Research article · 2019 Dosimetric Analysis of 3D-CT Image Based High Dose Rate Brachytherapy Treatment Planning of Carcinoma Uterine Cervix: Initial Experiences at Central India Government Institute
aimed to analyze the dose volume parameters (DVH) for target and OARs in high dose rate (HDR) ICBT treatment planning of carcinoma uterine cervix (Ca-Cx) patients. Our initial experiences ... were evaluated, who have…
Conference abstract · 18 Jun 2018 Erythemal UV dose rate spatial distribution using ozone monitoring instrument satellite data over Egypt
spatial distribution of Erythemal Ultraviolet Dose Rate (EUV) at noon in mW/m2 observations derived from the Ozone Monitoring Instrument (OMI) are presented over Egypt covering the geographical domain ... years. Finally…
Research article · 2 Apr 2018 High Dose Rate Intraluminal Brachytherapy (HDRILBT) as a Boost to External Beam Radiation Therapy (EBRT) in Advanced Inoperable Carcinoma Esophagus
patients who could be intubated with 16 F Levine’s tube was given high dose rate (HDRILBT) and formed the study group. The prescription point was at 1 cm from
Review article · 2018 Review of Pulsed Reduced Dose Rate Re-irradiation for Recurrent Tumors
Pulsed Reduced Dose Rate (PRDR) is an external beam re-irradiation technique that may be appropriate for recurrent tumors in patients who have previously undergone radiation treatment. PRDR is thought ... effectively…
Research article · 2018 Electromagnetic Tracking in High Dose Rate Brachytherapy - A Composite Analysis Model
Article · 2018 Electromagnetic Tracking in High Dose Rate Brachytherapy - A Composite Analysis Model
Electromagnetic tracking (EMT) in high dose rate Brachytherapy has to face a number of signal processing challenges which we summarize in this study. We propose a coherent signal processing chain
Research article · 2018 Indoor Radon Levels and the Associated Effective Dose Rate Determination at Al-Elaf Distinguish Secondary School for Girls in the Basrah Governorate, Ira
Study of indoor radon has been carried out in Al Elaf Distinguish

