Performance evaluation of tibia nail using finite element analysis and mechanical testing.
Background: Premature failure of the nail with an unstable fracture may lead
Articles, journals and conferences in one search. An exact title, DOI or ISSN is listed first.
In the search box: "exact phrase" · -leave out · OR · prefix* · title: author: journal:
Background: Premature failure of the nail with an unstable fracture may lead
objective of this study is to compare the results of proximal femoral nail intramedullary fixation device verses dynamic compression screw with extramedullary device in the treatment of peritrochanteric fractures…
bones. Different studies have been showing controversial results between Dynamic Hip Screw & intramedullary fixation devices historically. Aim: Aim of our study is to compare functional and clinical outcome of dynamic
over an intramedulary device. We compared changes in callus features in terms of shape, pattern and density both before and after infection. Limb lengthening over an intramedullary nail/rush ... index procedure. We used…
shape memory alloys. NiTi alloys have been used in orthopaedic device applications, such as osteotomy fixation staples and intramedullary implants owing to their unique shape memory effect, superelasticity, low elastic
shape memory alloys. NiTi alloys have been used in orthopaedic device applications, such as osteotomy fixation staples and intramedullary implants owing to their unique shape memory effect, superelasticity, low elastic
shape memory alloys. NiTi alloys have been used in orthopaedic device applications, such as osteotomy fixation staples and intramedullary implants owing to their unique shape memory effect, superelasticity, low elastic
considerable discomfort. Hence we preferred intramedullary nail devices which combines accuracy, minimal invasiveness, with patient compliance and with excellent functional outcome. Temporary external fixator used…
intramedullary nailing included less invasive surgery, undisturbed fracture hematoma and use of load sharing device support. Purpose of this study is to compare outcomes of each method of fixation ... were divided in…
operative and open reduction with internal fixation was the treatment of choice of displaced fractures, extra medullary and intramedullary devices may be used. Results: Good results in all cases with
Intramedullary nailing is one of the oldest types of surgical fracture treatment and is now considered a standard procedure for the surgical management in most tibia diaphysis fractures treatment. Although ... stability…
reduction with an intramedullary nail fixation. General anaesthesia time was approximately three hours and the airway was maintained with a size 5 i-gel device. Following extubation a large ulcer
BACKGROUND Intraarticular distal femur fracture has always been difficult to treat and
femoral fracture fixation using PFN and Intertan nail. Our study included 40 patients having peritrochantric femur fractures, segregated into two groups (on the basis of the intramedullary device
development of disposable surgical saw guides and cutting blocks in total knee arthroplasty. These devices help minimize tissue loss and optimize the native biomechanics of the patient. This review explores ... Sharkey…
disastrous complications associated with orthopaedic implants such as prosthetic joints and fracture fixation devices. Local inflammation results osteolysis and destruction of the surrounding soft tissues. Management of…
BACKGROUND There is no consensus about the best option of internal fixation for unstable intertrochanteric fractures of femur. This study aimed to evaluate the treatment effects of contra-lateral reverse ... femoral…
Foot and ankle injuries are common in both athletic and aging populations
Introduction: Intramedullary device considered as a load sharing device is one of the commonest surgeries now a days. From the era of straight nails, flexible nails to anatomically curved nails ... potentially closed…
compare the functional outcomes between the DHS and PFN for IT fracture fixation. METHODS This study is a retrospective comparative analysis of 455 patients with IT fractures ... presented as median. Statistical…
device was designed and built to apply torsional loads to the tibia. The test case was an oblique plain corrective osteotomy of a tibial diaphysis stabilized with an intramedullary nail ... axial DLRSA was not…
article an original surgical procedure is described combining Percutaneous Retrograde Intramedullary Pinning (PRIP) and open reduction with lag screw fixation in the treatment of displaced near three-part fractures…
For authors and organisers
Find the right journal for your paper and submit your manuscript.