Scholars Central

Research articlePublished 6 Mar 2021

Is Legacy Technique of Anatomically Bowed Ante Grade Intramedullary Device Fixed at Metaphysis Cancellous Bones and Single Proximal Screw Locking Suffice for Good Outcome in Femoral Fractures?

Authors: Vivek Amritbhai Patel, Vishal Ashokraj Pushkarna, Dhruvin J Patel, Smit Divyesh Bhai Dave, Pranay Bhatt

Journal of Research in Medical and Dental Science

Volume 9 · Issue 6 · Pages 319–324

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Introduction: Intramedullary device considered as a load sharing device is one of the commonest surgeries now a days. From the era of straight nails, flexible nails to anatomically curved nails have been used to fix the fractures of the femur. It provides biological environment to the fracture being a potentially closed reduction method. Objective: To measure the outcome of the method of femur fixation by anatomically curved interlocking nail & proximal single locking with two distal locking. Material & Methods: We have studied the (n=37) patients retrospectively. All the fractures treated with femur interlocking nail & proximal single (preferentially dynamic) locking .95% was males & 5% were females in our study. Mean age was 28 years. Fractures were classified by AO classification preoperatively. Results: Mean union time was 22 weeks. (n=34)92 % of patients had excellent outcome & (n=3) 8% had poor outcome. 91.80 % of patients had no limb length discrepancy.70.27% patients of excellent outcome had high velocity trauma & 75% were operated within ten days of trauma incidence. Injury & surgery interval has no effect on the results. Conclusion: Out of different methods of fixation our studied method was anatomically curved femur interlocking nail for treatment of femoral shaft fractures achieves good functional outcome. The single proximal screw allows shorter surgery time, prevents added stress risers at the base of neck & possibly primary dynamicity & callous micro motion. These devices can achieve good anatomical alignment & reduces the future chances of knee arthritis.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Journal of Research in Medical and Dental Science.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Research in Medical and Dental Science
  • SubjectDentistry & Oral Health
  • BylineArticles whose byline prints “Vivek Amritbhai Patel”
  • BylineArticles whose byline prints “Vishal Ashokraj Pushkarna”
  • BylineArticles whose byline prints “Dhruvin J Patel”
  • BylineArticles whose byline prints “Smit Divyesh Bhai Dave”
  • BylineArticles whose byline prints “Pranay Bhatt”