Data Logging System (DLS) for the measurement of parameters such as temperature, load current, load voltage and power have been designed and developed. These parameters are the time varying signals
temperature on photovoltaic (PV) module’s parameters e.g. open circuit voltage, short circuit current, load voltage, load current, power and efficiency. The effect of variation in solar intensity on “temperature
proposed compensate non linear load by improving the power factor to the desired value and also eliminate the harmonics under distorted Source voltage and source currents. A detailed synchronization circuit
parallel with a load and suppresses the harmonic current produced by the load and. reduce the total harmonic distortion (THD). The voltage source inverter (VSI) is the core ... results it is confirmed that the filter…
strategy allows proper load current sharing and avoids current circulation between the inverters. The control strategy used is droop control which consists of adjusting the output voltage frequency and amplitude…
adjacent feeders to compensate for supplyvoltage and load current imperfections on the main feeder and full compensation of supply voltage imperfections on the other feeders. In this paper ... controller has performed…
DPFC) capable of simultaneous compensation for voltage and current in multibus/multifeeder systems. In this configuration, one shunt voltage-source converter (shunt VSC) and two or more series VSCs ... exist. The system…
electronic circuit that maintains a constant output voltage irrespective of change in load current or line voltage. Many different types of voltage regulators with a variety of control schemes
keeping resistance 124 Ω and capacitance 15μF. Load voltage and current waveforms were recorded for all combinations by using Gold wave software having duration of 1s with sampling rate ... From the investigations it is…
allows the possibility of generating thirteen voltage levels while using a single DC source. The proposed inverter has, hence, a reduced impact on loads systems resulting on a good energetic ... passive components. A…
high output dc voltage dc generation systems. It provides continuous input current to load with low ripple voltage and current. Voltage stress on the all switching device, diodes, and capacitors
Total Harmonics Distortion (THD), Switching Stress, Efficiency of the Inverter, Variations in the load voltage and current. The simulation studies reveal that the best switching sequence presents in SVPWM provides
linear loads. A 3-phase voltage source inverter bridge with a dc bus capacitor is used there as an active filter (AF). A PWM current control is used to generate ... from load currents, dc bus voltage and source voltage…
optimal location of STATCOM.Simulation models are developed for linear and nonlinear load. Analysis of voltage and current harmonics is performed for these loads individually. Wind turbine connected to synchronous…
been increasing due to the wide use of nonlinear loads,which cause harmonic currents in networks and consequently distort the voltage and current at the point of common coupling. This ... voltage and current harmfully…
cost. Unfortunately, it causes unintended distortions in the output voltage and current. When connected to the grid under non-linear loads conditions it cause the voltage instability. In this paper ... drawbacks. The…
power quality, by comparing the mitigated voltage and current THD values among DSTATCOM, DVR & UPQC connected to a system with a distorted load. There after a novel design of UPQC ... implemented using PI-Resonant…
buck boost converter in such a way that with variation in load, the varying input current and voltage to the converter follows the open circuit characteristic of the PV array ... closely. At various insolation levels…
significant economic losses in few moments. Probable power quality problems are, e.g. harmonics, flicker, voltage dips and supply interruptions. The power quality may be improved by using filters and compensators…
microbial fuel cells were designed and loaded with a 1000 Ω external load (resistor). Electrical voltage, current, power output was measured on weekly basis. Current density and power density were
frequency tracking and to extract the harmonic spectra of the grid voltage and the load currents in the microgrid. Also this paper high lights on DG grouping in order
load current harmonics, load reactive power demand and load neutral current. For this purpose, this paper analyses current controlled four leg voltage source inverter made of insulatedgate bipolar transistor connected…
Power quality problem is an occur as a non-standard voltage, current and frequency. Electronics devices are very sensitive load against harmonics. In power system voltage sag, swell, flicker
even under unbalanced and nonlinear load conditions. This type of loads results in unbalance and distorted stator voltage and current with subsequent power quality degradation and electromagnetic torque pulsations…
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.