Highly uniform, sub-micrometer surface patterns have been actively investigated as non-chemical means of surface engineering. Surface functionalities such as wetting, friction and optical effects can be engineered…
monomer units, and their combination. This paper describes a novel method to prepare micrometer-sized giant vesicles composed of an amphiphilic poly(methacrylic acid)-block-poly(methyl methacrylate-random-methacrylic…
then they were embedded in paraffin. Histological sections have a thickness not exceeding 6 micrometers. Then there are dyeing by hematoxylin and eosin according to Van-Gison technology. Morphometric study ... central…
nobody has reported these attractive flowers like ZnS structures in the range of micrometer. The present study provides a new avenue to gain in-depth insight to the design
specifically designed movable computer ruler (MCR) derived from digital images of a stage micrometer. Subsequently, MCR can be superimposed on images of parasites to measure their dimensions in microns ... derived from…
stomata were scale-dependent, a pattern of regularity at scales below about 150 micrometers, clustering beyond 220 micrometers, and random between the two scales. Elevating CO2 concentration led to more ... regular…
molecular printing which involves the controlled deposition of molecules on a substrate at the micrometer scale. These approaches have developed tremendously in the past few years and micropatterned substrates…
GCIPL thickness was thinner in eyes with glaucoma in comparison to controls (70.64 ± 12.24 micrometers versus 79.58 ± 0.51 micrometers). Mean RNFL thickness in eyes with glaucoma was thinner compared with ... controls…
associated mechanical and thermal properties. The simulation of this process on nanometer to micrometer scale allows for a better understanding and prediction of the material composition and properties ... variability…
inclusion of 2D nanosheets in PVdF-HFP skeletons, combined with the multiscale pores (several micrometers + sub-micrometers) originally generated by means of the controlled phase inversion, can generate additional ionic
size analyses of the powders were carried out by microscopic technique using eye piece micrometer. Around 600 particles were counted avoiding the aggregates and the data obtained was plotted
Lipid emulsions are safely infused when particle diameter ranges between 0.4 and 1.0 micrometers (like chylomicra), according to European guidelines. No data exist on Fish Oil stability when added ... particle diameters…
pore size for scaffolds in bone tissue engineering was set between 300 and 500 micrometers. These values appeared reasonable since they fall in line with the diameter of osteons. More ... recently, 2 papers showed that…
background gases was detected by a cooled MCT detector in the range 4.5-11.6 micrometer, using long-pass filters. The spectra were taken in argon, helium and also in nitrogen ... background corrected and noise filtered…
squeezable, had a very low thermal conductivity like air and much larger pore sizes (micrometer range, 30-250 mm) than those synthesized from high purity cellulose fibers (nanometer range
Micrometer-sized giant vesicles are a model of biomembranes for mitochondria and erythrocyte. In recent years, the giant vesicles have been expected as carriers for drug delivery systems as well ... methacrylate…
nanometer-sized DNA tiles (A + B) through sticky end cohesion gave rise to a micrometer-sized porous giant-sheet material. The synthesized DNA-NPS exhibited a uniformly distributed porosity with
For authors and organisers
Publish, present and keep up with your field
Find the right journal for your paper and submit your manuscript.