accurate identification of harmonic disturbances in order that remedial measures can be taken for the improvement of power quality. This paper presents a new method based on discrete wavelet transform ... identification…
prove the feasibility of 17N detection as a new redundant channel for reactor power measurement. In TRR, similar to other pool type reactors, neutron detectors are immersed in the pool ... around the core as the main…
Present paper proposes a power measurement technique of a single phase electrical load. The proposed method is a low cost power measurement technique. The load which is taken into consideration ... input signals. In…
This paper presents a measurement system of 3 phase power supply system using MAXIM chip MAXQ3183 and Philips microcontroller P89V5RD2. Hardware is created to sense the voltage and current from ... MAXIM chip. Further…
higher powers that today have reached as much as 100kW and above. Measuring the power and beam quality of such high powers is an increasing challenge. Ophir has developed ... power meter capable of measuring up to 120kW…
overhead conductor systems. The Power Donut2 is completely self-contained. it is self-powered, it measures current ,voltage, MW, MVars, MWh ,conductor temperatures, stores data on board, and it transmits
crystals cleaved in liquid helium are presented in Figure 1. All spectra have been measured with the same apparatus under the same condition. As the deuterium concentration increases, the long ... that the value of Eg…
laser operation in industrial processes. In this study, a novel technique of fiber laser power measurement is presented. We have used a sensor representing a segment of single-mode optical ... metal layer, which was…
characteristics are chosen. Analytical field measurements of 10kWp PV systems, located in different regions of Greece, were performed by means of a Class A Power Analyzer. The data gathered were ... characteristics…
peak power (r=0.70, p=0.001), and CMVJ and SLJ (r=0.57, p=0.001). There were no correlations between TEST and performance measures (SLJ, r= -0.03; CMVJ ... Total TEST levels are not correlated with performance measures…
type and place. This paper describes graph theoretic approach to solve the measurement placement problem for power system state estimation. The measurement configuration is designed for IEEE 14 bus system ... processing…
This paper describes a heuristic approach for optimal placement of phasor measurement units (PMUs) in power system for improving state estimation accuracy. PMUs are able to measure highly accurate ... buses at which…
Taking measurements of neutron power in absolute units is a complicated procedure, and the corresponding measurements are not carried out, if possible, being replaced with results of measuring the neutron ... power in…
insulating properties of materials at various temperature under various DC electric field, while the measurement system for it is simple and not so expensive. Furthermore, since the method is applicable ... insulating…
Temperature difference (Outlet temperature- Inlet temperature) is proportional to the thermal power produced by each channel. Since measurement of out let temperature using instruments in all the channels