position sensorless BLDC drive simulated, in this paper, is based on detection of zero crossing from the terminal voltages differences. This method relies on a difference of line voltages measured ... line voltages…
simultaneous estimation of Diacerhein and Aceclofenac in tablets by using first order derivative zero-crossing method. Aceclofenac showed a zero crossing point at 275.8 nm while Diacerhein showed a zero
simultaneous estimation of Edaravone and Citicoline Sodium in synthetic mixture using first order derivative zero-crossing method. Edaravone showed zero crossing point at 245.60 nm while Citicoline Sodium showed zero…
derivative spectroscopic method was used for simultaneous determination of ezetimibe and rosuvastatin using the zero-crossing technique. The measurements were carried out at wavelengths
were determined at 270.8 nm and 260.6 nm. Method B is first derivative zero crossing point method (FDZ) where LAM and TEN were determined ... used as the divisor) of the zero order divisor spectra were measured for the…
methanol: water and scanned in UV- region for first order derivative spectrum. The zero crossing point for atorvastatin calcium and aspirin was 243 nm and 276 nm respectively. Linearity
their quantification measurement of the two drugs in their binary mixtures, the zero crossing of the wavelengths detected, and calibration curves were depicting the linearity. The wave length were found
back EMF difference. The commutation point of the drive is determined by detecting the Zero Crossing Point (ZCP) of difference in back EMF of two phases. Simulations of the proposed
Linear Predictive Coding (LPC) Analysis, Dynamic Time Wrapping (DTW), Relative Spectra Processing (RASTA) and Zero Crossings with Peak Amplitudes (ZCPA).Some parameters like RASTA and MFCC considers the nature
spectrophotometric method was based on the estimation of both the drugs at their respective zero crossing point (ZCP). The first-order derivative spectra were obtained at N = 1 (scaling factor
rotor position or rotor angle. In this paper rotor position is determined by the Zero Crossing Detection (ZCD) of back emf. Unlike old methods of calculating Back
form has been developed. The method is based on the derivative spectrophotometric method at zero-crossing wavelengths. Two wavelengths 280nm (zero crossing point for NEB) and 272.2nm (zero crossing
derivative method is based on the measurement of absorbance of one drug at the zero crossing point of another drug. Candesartan Cilexetil and Hydrochlorothiazide were determined at two different wavelengths ... zero…
explicitly determine the spatial distribution of the mechanical properties of the tissue. Normalized cross correlation has the best performance of time-delay estimation in ultrasonic signals. However, the acquired…
developed for simultaneous estimation of rosuvastatin calcium and aspirin by employing first order derivative zero crossing method in methanol. The first order derivative absorption at 256.3 nm (zero cross point…
hydrochloride and Glimepiride is antidiabetic drug. A sensitive, precise, accurate and simple first order zero crossing UV spectrophotometric method has been developed for simultaneous Estimation of Pioglitazone…
tablet dosage form, using 0.5 % w/v sodium lauryl sulfate in distilled water. The zero-crossing point in the first order derivative spectra was employed for their estimation ... shows measurable derivative absorbance at…
warnings by using ECG biometric algorithms. Two methods of detection were analysed, comprising modified zero-crossing and wavelet based methods. An average heartbeat was generated for each person by randomly…
developed. Method (I) is first derivative spectrophotometric method, derivative amplitudes were measured at the zero crossing wavelength of 289 and 249.5 nm for determination of RIV and CLP, respectively