Case reportPublished 8 Jul 2017
An unusual complication during implantation of an internal cardioverter-defibrillator: A Case Report
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Subclavian arteriovenous fistulas are a rare but known complication of catheterisation procedures, pacemaker and internal cardioverter-defibrillator (ICD) implantation and surgery. These fistulas typically become apparent few days after procedure through clinical signs of a high output circulation. However, small fistulas can remain asymptomatic. We describe a case of a chronic Subclavian Arteriovenous Fistula (AVF) complicating an otherwise straightforward ICD device implantation procedure. The patient required urgent endovascular treatment to close the fistula.
Subjects
CardiologyAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalCurrent Research: Cardiology
- SubjectCardiology
- BylineArticles whose byline prints “Shveta Monga Mbbs Mrcp”
- BylineArticles whose byline prints “Atique Imam Mb Bs Frcs Frcr”
- BylineArticles whose byline prints “Richard Bulbulbia Ma Md Frcs”
- BylineArticles whose byline prints “Paul Foley Md Frcp”
- BylineArticles whose byline prints “William Mc Crea Mb Bch Frcp”
- BylineArticles whose byline prints “Badrinath Ch”
- BylineArticles whose byline prints “Rasekaran Bsc Md(res) Frcp”