Scholars Central

Case reportPublished 9 Aug 2016

Retrieval of a firmly impacted knotted coronary catheter through the contralateral femoral artery using a balloon angioplasty catheter

Authors: Syed Hasnain Mujtaba, Finn Farquharson, Samer Arnous, Magdi El-omar

Current Research: Cardiology

Volume 1 · Issue 2 · Pages 107–110

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Knotting of a coronary catheter during cardiac catheterization is a relatively common event and can usually be resolved by simply untwisting the catheter or by straightening it with a guidewire. If these manoeuvres fail, the knotted catheter may be retrieved using a snare device; however, if unsuccessful, surgical extraction may prove necessary. The authors describe a case in which a snare device failed to retrieve a knotted catheter firmly impacted within a loop in the external iliac artery. The catheter was successfully mobilized using an angioplasty balloon inflated distal to the site of impaction then pulled back, allowing dislodgement of the knot and subsequent extraction of the catheter from the contralateral femoral artery.

Subjects

Cardiology

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Current Research: Cardiology.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalCurrent Research: Cardiology
  • SubjectCardiology
  • BylineArticles whose byline prints “Syed Hasnain Mujtaba”
  • BylineArticles whose byline prints “Finn Farquharson”
  • BylineArticles whose byline prints “Samer Arnous”
  • BylineArticles whose byline prints “Magdi El-omar”