Research articlePublished 21 Sep 2016
Corrosion of copper plated NST60Mn and NST50 steels in NaCl, H2SO4 and NaOH solutions
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
The corrosion characteristics of copper-electroplate on two Nigeria standard steels (NST60Mn and NST50) in three corrosive media (0.1M NaOH, 3.5M NaCl, 0.1M H2SO4 solutions) were studied. NST60Mn and NST50 steels substrates were plated in acid sulphate bath. The results of copper corrosion study in three corrosive media after 30 days revealed that copper plated steels have lower corrosion rates than the naked as-received steels whereas the copper-coated steels have 3.06 x 10-3, 6.46 x 10-4, and 1.2 x 10-3 corrosion rates (mgmm-2day-1) in 3.5M NaCl, 0.1M H2SO4, and 0.1M NaOHrespectively. These will produce a good combination with some other more protective metal plating over coats when used in these environments.
Subjects
Materials ScienceAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalDer Chemica Sinica
- SubjectMaterials Science
- BylineArticles whose byline prints “Olawale O. Ajibola”
- BylineArticles whose byline prints “Funso Kolawole”
- BylineArticles whose byline prints “Abdullahi O. Adebayo”