Effect of rapid ventricular pacing on cerebral oxygenation in transcatheter aortic valve implantation (TAVI): role of routine near-infrared spectroscopy monitoring

Authors: Pelin Karaaslan, Kamil Darçin, Arda Özyüksel, Esra Kutlu, Emine Arzu Köse, Bilal Boztosun, Atif Akçevin

Biomedical Research

Volume 28 · Issue 7 · Pages 3176–3181

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Objective: Transcatheter aortic valve implantation has become an important treatment modality in patients with high risk comorbidities for surgical aortic valve replacement. The objective of this study is to evaluate the cerebral perfusion status using near infrared spectroscopy method especially during the rapid ventricular pacing phase of the transcatheter aortic valve implantation procedure. Methods: 20 consecutive patients undergoing trans-femoral aortic valve implantation procedure between May 2015 and March 2016 in our institute were retrospectively evaluated. The periprocedural cerebral oxygenation was measured with a near infrared spectroscopy sensor (INVOSTM-5100 C, Medtronic Inc., Minneapolis, MI, USA) located on the forehead of the patients. All hemodynamic data and cerebral near infrared spectroscopy values were recorded before, during and after the procedure with constant time intervals, especially at the time of rapid ventricular pacing and device deployment. Results: The mean age was 74.4 ± 9.2 years. Male female ratio was 1.8 to 1 (13 males, 7 females). Mean procedure time was 70.2 ± 14.3 minutes. The rapid ventricular pacing included two episodes with a total time for pacing of 22.6 ± 5.1 seconds. There was a statistically significant difference with regard to the heart rate and the cerebral near infrared spectroscopy values (p=0.006 and p=0.02; respectively) in all patients during the rapid ventricular pacing period. The cerebral near infrared spectroscopy values were statistically lower than baseline levels (p<0.001). Conclusion: This observational study presents the significant decrease of cerebral near infrared spectroscopy values during the rapid ventricular pacing phase of the transcatheter aortic valve implantation procedure. Further studies may reveal cut-off values both for near infrared spectroscopy values and rapid ventricular pacing duration in order to determine a critical cut-off level.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Biomedical Research.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalBiomedical Research
  • SubjectPathology & Lab Medicine
  • BylineArticles whose byline prints “Pelin Karaaslan”
  • BylineArticles whose byline prints “Kamil Darçin”
  • BylineArticles whose byline prints “Arda Özyüksel”
  • BylineArticles whose byline prints “Esra Kutlu”
  • BylineArticles whose byline prints “Emine Arzu Köse”
  • BylineArticles whose byline prints “Bilal Boztosun”
  • BylineArticles whose byline prints “Atif Akçevin”