Scholars Central

Case reportPublished 2016

Recanalisation of Totally Occluded Modified Blalock Taussig Shunt by Balloon Angioplasty 48 Hours after its Construction

Authors: N Hanna, T Smaira, A Fenianos, O Safi, Z Saliba

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

An 18 months old boy with TOF benefited from a BTS. Deep cyanosis reappeared 48 hours later and continuous flow profile of the shunt could not be identified by Doppler echocardiography. At catheterization, angiogram confirmed complete shunt occlusion. The shunt was recanalized using a coronary guide wire and a 4mm diameter balloon. The SpO2 improved and repeated Doppler echocardiography showed the patency of the shunt during follow-up. Four days later, he developed a severe febrile pneumopathy due to RSV and died 2 days later. The shunt patency was documented 2 hours before death.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Intensive and Critical Care
  • SubjectAnaesthesia & Pain
  • BylineArticles whose byline prints “N Hanna”
  • BylineArticles whose byline prints “T Smaira”
  • BylineArticles whose byline prints “A Fenianos”
  • BylineArticles whose byline prints “O Safi”
  • BylineArticles whose byline prints “Z Saliba”