Review article · 9 Aug 2024
Research articlePublished 27 Mar 2020
Development and Validation of a Quantification Method of Cotinine in Urine Using Two Innovative Technologies: Supported Liquid Extraction and QDa Detection
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Objective: Cotinine is the best biomarker of tobacco smoke exposure because of its long half-life. Several methods are developed to quantify cotinine in biological fluids, including high performance liquid chromatography. This method requires an extraction step in order to clean-up the sample and concentrate the analyte of interest. The aim of this study was to optimise the extraction step and to develop an easy, reproducible and specific method to measure cotinine in urine. Methods: An extraction of neutrals was chosen and performed by Supported Liquid Extraction (SLE). SLE consists in liquidliquid extraction in the presence of a sorbent enabling efficient extraction with less organic solvent and without any emulsion formation. Urine was basified by treatment with NH4OH in order to neutralise cotinine before loading on SLE plate. After drying, neutrals were eluted with a mix containing dichloromethane and isopropyl alcohol. Solvent was then evaporated and samples were reconstituted with water. Detection of cotinine was performed by mass detection using a QDa detector after UHPLC separation with a C18 column at a flow rate of 0.4 ml/min. A gradient elution of H2O +0.1% NH4OH and CH3CN was used. The method was validated based on linearity, precision, recovery and limits of detection and quantification. Results: The range of linearity was 0.001 µg/ml -5 µg/ml with a determination coefficient of 0.997. The precision was evaluated by the Relative Standard Deviation (RSD) for intra- and interassay and was below 5% and 10% respectively. 3 levels of concentration were tested to assess the recovery rate which was consistent and higher than 96%. Conclusion: Cotinine concentration can be measured in urine by SLE extraction and UHPLC-QDa detection. This method is easy, reproducible and allows quantification of low concentrations. It is a good solution to assess patients’ tobacco smoke exposure in medical laboratory.
Keywords
Subjects
Pathology & Lab MedicineAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
More from this journal
The newest in Journal of Diagnostic Techniques and Biomedical Analysis.
Opinion · 29 Dec 2023
Molecular Diagnostics: Decoding Disease at the Genetic Level
Opinion · 29 Dec 2023
From Data Streams to Diagnoses: AI's Journey in Healthcare
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Diagnostic Techniques and Biomedical Analysis
- SubjectPathology & Lab Medicine
- BylineArticles whose byline prints “Marie-Lise Colsoul”
- BylineArticles whose byline prints “Nicolas Goderniaux”
- BylineArticles whose byline prints “Dominique Vanpee”
- BylineArticles whose byline prints “Laurence Galanti”
