Conference abstractPublished 11 Dec 2025
Analysis and 3D correction of glenoid dysplasia with metal hemi-wedge base plate augment: short term radiographic outcomes
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Background Glenoid defects can be addressed traditionally by asymmetric reaming or by bone-preserving correction to a more lateral joint line by bone or metal augmented baseplates in reverse shoulder arthroplasties. While there is more evidence in literature regarding the outcome and complications of Bony Increased Offset Reversed Shoulder Arthroplasty (BIO-RSA), there is minimal reported experience with the outcome after metal glenoid augments. The aim of this study was to determine whether a metal augment can correct the glenoid deformity in an anatomic manner. Methods Glenoid morphology and deformity were determined in 50 patients with Walch type B1, B2, D and Favard type E0â??E3 glenoid defects using preoperative radiographic and computed tomography (CT) analysis. All patients received a preoperative planning CT with 3D planning, and measurements of glenoid inclination (in 3 planes proximal, middle, distal), reversed shoulder arthroplasty angle (RSA) and glenoid version were obtained. All patients had a pathologic inclination in the coronal or frontal planes of > 10ÃÂ?°. Above the threshold of 10ÃÂ?° pathological glenoid version or inclination metal hemi-augments of 10ÃÂ?°, 20ÃÂ?°, or 30ÃÂ?° were used which allow an individual 360ÃÂ?° augment positioning according to the patient glenoid deformity. Results The mean preoperative numbers of the glenoid version demonstrate that most glenoids were in retroversion and superior inclination. In total 2410ÃÂ?° wedges, 1820ÃÂ?° wedges and 8 30ÃÂ?° wedges were used. In the majority of cases, the wedge was positioned posteriorly and/or cranially between 10:00 and 12:00 oâ??clock, which allows a correction in a 3D manner of the glenoid inclination and version. The mean RSA angle could be corrected from 22.76 ÃÂ?± 6.06 to 0.19ÃÂ?° ÃÂ?± 2.7 (p < 0.0001). The highest retroversion of the glenoid is evidenced in the proximal section and it could be corrected from â?? 23.32ÃÂ?° ÃÂ?± 4.56 to â?? 6.74ÃÂ?° ÃÂ?± 7.75 (p < 0.0001) and in the middle section from â?? 18.93ÃÂ?° ÃÂ?± 3.35 to â?? 7.66ÃÂ?° ÃÂ?± 5.28 (p < 0.0001). A mean sphere bone overhang distance (SBOD) of 5.70 ÃÂ?± 2.04 mm was found in order to avoid or minimize relevant scapular notching. Conclusion By using a new 360ÃÂ?° metal-augmented baseplate, the preoperative pathological inclination and retroversion can be corrected without medialization of the joint line. Future clinical results will show whether this bone-preserving procedure improves also the clinical outcomes as compared to asymmetric medialized reaming or wedged BIO-RSA.
Subjects
SurgeryAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalSurgery: Current Research
- SubjectSurgery
- BylineArticles whose byline prints “Luis Navas”