Scholars Central

Conference abstractPublished 19 Oct 2018

The development of a novel 3D printed prototype device to simplify blood cell subset enrichment at clinical sites

Authors: Daniel Horowitz, George Szabo, Rudolf Cedro Jr, Ling-Yang Hao

Janssen Pharmaceutical Companies of Johnson & Johnson, USA

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Peripheral blood collection is a relatively non-invasive way to obtain biomarkers during clinical trials. Protein and gene expression changes can be used to assess drug/target engagement and disease state changes. To avoid functional changes in blood cells during storage, cells need to be stored in appropriate buffers. For gene expression analysis, whole blood can be collected in buffers that lyse the cells and protect RNA from degradation, but this obscures changes that may be found only in specific cell types. The separation of specific subsets requires instrumentation and trained personnel not readily available at many clinical sites, and shipping to a processing lab may affect the results. Therefore, a way to enrich for and stabilize blood cell subsets at the site of collection is needed. We have developed a portable 3D printed prototype device that can be operated with minimal training. Blood is collected into a tube containing commercially available polystyrene spheres (PluriSelect) coupled to an antibody specific for a blood cell surface antigen. After a 10 min incubation at room temperature, the tube is inserted into the device, followed by a single washing step. Between the inlet and outlet is a mesh with pores that are smaller than the polystyrene beads. All of the blood cells attached to the beads will remain on the mesh, while the unbound cells will pass through the filter. Using anti-CD3 antibodies, we were able to use FACS to verify that the device is capable of enriching more than 1,000,000 CD3+ cells from 2ml of whole blood with 90% purity. At a clinical site, these cells can be collected and processed at room temperature with minimal manipulation and stored in the appropriate buffer and transported. This prototype device may enable cell type-specific analysis for pharmacokinetic/pharmacodynamic assessments and biomarker discovery.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Clinical and Cellular Immunology
  • SubjectImmunology & Microbiology
  • BylineArticles whose byline prints “Daniel Horowitz”