Biomaterials characterization and pedicle screws fixation in lumbar spine: A review

Authors: Shri N Dubey, Jamal Ghorieshi

Miami University Oxford, USA; OH Wilkes University, USA

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Instability of the lumbar spine is caused by various factors that include degenerative disc, herniated disc, traumatic, and other disorders. Pedicle screws are widely used as a main fixation device to construct rigid linkages of vertebrae to be fully functional and stable. Other various technologies and methods have been used to restore the stabilization. Loosening of pedicle screws has been the main cause of concerns. This could happen either errors in installing processor very poor boon qualities due to osteoporosis. Additionally, Shear force and tension/compression force would change as spine goes through different phases such as extension, flexion, bending and rotation. The pullout strength of augmented pedicle screws was increased in both primary and salvage procedures by 119% (p = 0.001) and 162% (p = 0.01), respectively. Self-centering pedicle screws at different trajectories (0°, 10°, 20°, and 30°) showed the same pullout strength as inserted in a straight-ahead trajectory. The outer cylindrical and inner conical shape of pedicle screws showed the highest pullout strength in Grades 5 and 15 foams (synthetic bone). An outer cylindrical and inner conical shape with a V-shape thread showed the highest pullout strength in all foam grades. The maximum pullout strength was observed at axial pullout configuration at 0°. For the Grade 15 (240 kg/m3 ) foam, there was the decline in pull out strength. The decrease in pullout strength was highest for Grade 10 (160 kg/m3) foam. The maximum pullout strength of 2176 N (0.32-g/cm3 Sawbones) on all densities. Type 1 Pedicle screw showed the best fixation due to smaller conical core diameter and smaller thread pitch (Screw 2, 2 mm; Screws 1 and 3, 3 mm).

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Journal of Clinical and Cellular Immunology.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Clinical and Cellular Immunology
  • SubjectImmunology & Microbiology
  • BylineArticles whose byline prints “Shri N Dubey”
  • BylineArticles whose byline prints “Jamal Ghorieshi”