Conference abstractPublished 1 Oct 2018
Modification of biomechanical properties of cornea with different UV corneal cross-linking protocols ex vivo
Ufa Eye Research Institute, Russia
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Aim: Collagen cross-linking (CXL) with UV-A irradiation 370 nm and 0.1% riboflavin stabilizes the pathological process in the cornea. Improvement of the standard UV-A corneal cross-linking resulted in accelerated and pulsed-light accelerated UV-A cross-linking. It is necessary to compare these UV cross-linking techniques to assess its efficacy. Methods: The experiments were carried out on 36 porcine eyes in 4 groups (8 porcine eyes each) ex vivo: 1st group â?? intact (control); 2nd group â?? standard UV-A corneal cross-linking (S-CXL) â?? 3 mW/cm2, 30 min; 3rd group â?? accelerated UV-A corneal cross-linking (A-CXL) â?? 18 mW/cm2, 5 min; 4th group â?? pulsed-light accelerated UV-A corneal cross-linking (Pl-ACXL) â?? 18 mW/cm2, 10 min, pulsed exposure (1 sec on/1 sec off). In all experimental groups Epi-Off, UV-A light 370 nm and 0.1% Riboflavin + 20% Dextran was used. The flaps from the cornea were stretched until they were completely ruptured using a universal tensile testing machine. Biomechanical properties were assessed by the force at rupture and the Young's modulus. Results: All investigated methods of UV-A cross-linking led to an increase in the force at rupture and the Young's modulus of the porcine corneas. Young's modulus increased: S-CXL by 98±12.1%, A-CXLâ??86±9.4% and Pl-A-CXLâ??89±10.2%. Ultimate tensile strength increased: S-CXL by 67.8±9.5%, A-CXL-55.3±7.2%, Pl-A-CXL-58±8.1%. The maximum results of biomechanical strength were obtained in the S-CXL group. However, statistically significant difference between standard, accelerated and pulsed-light accelerated UV-A corneal cross-linking was not obtained. Conclusions: Standard, accelerated and pulsed-light accelerated UV-A corneal cross linking increased the biomechanical properties of porcine corneas ex vivo and Young's modulus. Standard UV-A corneal cross-linking had slight advantage.
Subjects
Ophthalmology & OptometryAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Clinical and Experimental Ophthalmology
- SubjectOphthalmology & Optometry
- BylineArticles whose byline prints “Azat Khalimov”
- BylineArticles whose byline prints “Mukharram Bikbov”
- BylineArticles whose byline prints “Liliya Khalimova”
- BylineArticles whose byline prints “Emin Usubov”