Scholars Central

Review articlePublished 27 Mar 2024

Exercise and Real-world Training Using Pulse Rate Variability: A Systematic Review of Wearable Photoplethysmography Technology and Real-world Interventions

Authors: Michael R. Coggins

Journal of Health & Medical Informatics

Volume 15 · Issue 2 · Pages 1–10

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Background/Rationale: Photoplethysmography (PPG) may enable large-scale, accurate and cost-effective measurement of Pulse Rate Variability (PRV) as a surrogate for Heart Rate Variability (HRV) to inform real-world training of athletes. A significant body of research has investigated HRV as a non-invasive composite measure of cardio-autonomic function with application to exercise interventions and training protocols for athletes and athletics. However, the rapidity of commercialization of PPG-based wearables raises the question of what clinical research exists to enable realworld usage analogous to HRV-based wearables. PPG from wearable devices is a fundamentally different technology than the Electrocardiogram (ECG). Similarly, HRV and distally measured PRV may represent different underlying physiological processes or time courses. Aim: Perform a literature search of all exercise, athletic training, and athletic performance research using commercial wearable devices with PPG. Methods/Conclusions: The major gap in understanding of PRV measurement is how to use results to inform real-world training protocols and interventions. Few papers were found evaluating PRV measured by PPG technology for athletes, exercise, or training recommendations. Over half of the literature search findings are devoted to custom devices/software or would be difficult to replicate for field usage. Only a few studies examined PRV over time periods necessary for training adaptations and no studies were identified that tested varied exercise protocol micro/ macro-cycles. We recommend both more clinical studies of PRV from PPG technology to stratify underlying physiological mechanisms of value for athletics, and real-world studies to inform progressive exercise training methods and benefits/limitations of PRV outside of the clinical lab.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Journal of Health & Medical Informatics.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Health & Medical Informatics
  • SubjectComputer Science & IT
  • BylineArticles whose byline prints “Michael R. Coggins”