Scholars Central

Conference abstractPublished 2015

The accuracy of a designed software for automated localization of craniofacial landmarks on CBCT images

Authors: Ehsan Bahrampour, Elham Soltanimehr, Shoaleh Shahidi, Ali Zamani, Morteza Oshagh, Marzieh Moattari, Alireza Mehdizadeh

Shiraz University of Medical Sciences, Iran

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Background: Two-dimensional projection radiographs have been traditionally considered the modality of choice for cephalometric analysis. To overcome the shortcomings of two-dimensional images, three-dimensional computed tomography (CT) has been used to evaluate craniofacial structures. However, manual landmark detection depends on medical expertise, and the process is time- consuming. The present study was designed to produce software capable of automated localization of craniofacial landmarks on cone beam (CB) CT images based on image registration and to evaluate its accuracy. Methods: The software was designed using MATLAB programming language. The technique was a combination of feature-based (principal axes registration) and voxel similarity-based methods for image registration. A total of 8 CBCT images were selected as our reference images for creating a head atlas. Then, 20 CBCT images were randomly selected as the test images for evaluating the method. Three experts twice located 14 landmarks in all 28 CBCT images during two examinations set 6 weeks apart. The differences in the distances of coordinates of each landmark on each image between manual and automated detection methods were calculated and reported as mean errors. Results: The combined intra-class correlation coefficient for intra-observer reliability was 0.89 and for inter-observer reliability 0.87 (95% confidence interval, 0.82 to 0.93). The mean errors of all 14 landmarks were <4 mm. Additionally, 63.57% of landmarks had a mean error of <3 mm compared with manual detection (gold standard method). Conclusion: The accuracy of our approach for automated localization of craniofacial landmarks, which was based on combining feature-based and voxel similarity-based methods for image registration, was acceptable. Nevertheless we recommend repetition of this study using other techniques, such as intensity-based methods

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Diagnostic Techniques and Biomedical Analysis
  • SubjectPathology & Lab Medicine
  • BylineArticles whose byline prints “Ehsan Bahrampour”
  • BylineArticles whose byline prints “Elham Soltanimehr”
  • BylineArticles whose byline prints “Shoaleh Shahidi”
  • BylineArticles whose byline prints “Ali Zamani”
  • BylineArticles whose byline prints “Morteza Oshagh”
  • BylineArticles whose byline prints “Marzieh Moattari”
  • BylineArticles whose byline prints “Alireza Mehdizadeh”