Scholars Central

Conference abstractPublished 10 Aug 2017

Summary of clinical outcomes of corneal crosslinking using CCL-vario device

Authors: Sheng-Chieh Huang

Photon Medical Technology Co, China

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

We will present summary of clinical outcomes of corneal crosslinking using CCL-vario device. CXL is widely accepted as an effective strategy for stopping progression of keratoconus and ectasia after refractive surgery. CXL using Dresden protocol with 30 minutes Riboflavin instillation and 3 mW/cm2 irradiation has been proved safe and effective. In recent years, accelerated CXL was developed with higher irradiation intensity (9-30 mW/cm2) can theoretically shorten surgery time (4-10 minutes) and reduce discomfort of patients. However, it still needs more clinical evidences to evaluate the safety and effectiveness of accelerated CXL. Here we used MEDLINE to identify all CXL studies on keratoconic or ectasic eyes [n>6, follow-up >3 months, using CCL-365 various system (3-18 mW/cm2)] and compared the clinical data of traditional and accelerated CXL. In 3 mW group: 3 studies and 120 eyes were included, for visual acuity (logMAR UDVA, CDVA) and Kmax, at latest follow-up 100% studies reported improvement. In 9 mW group: 4 studies and 99 eyes were included, for visual acuity and Kmax, at latest follow-up, 50% vs. 100% studies reported improvement. In 18 mW group: 10 studies and 456 eyes were included, for visual acuity and Kmax, at latest follow-up, 40% vs. 70% studies reported improvement. On the other hand, stromal edema, haze were reported in all 3 groups within first 3 months and disappeared at latest follow-up. There is no severe complication including keratitis, prolonged haze or scarring was reported. These clinical results showed accelerated CXL also can stop corneal ectasia without significant complication although corneal stiffening effect was not compared in 3 groups. In conclusion, accelerated CXL (9-18 mW/cm2) may achieve similar efficacy of traditional CXL without significant safety problems.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Journal of Clinical and Experimental Ophthalmology.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Clinical and Experimental Ophthalmology
  • SubjectOphthalmology & Optometry
  • BylineArticles whose byline prints “Sheng-Chieh Huang”