Scholars Central

Conference abstract

Advantages of the extra corneal diaton tonometry in patients before and after photo refractive intervention

Authors: Margarita Rozhdestvenskaya, Munster, Dr. Alexey Dashevsky, Munchen, Prof. Dr.-Ing. Dr. habil. Konstantin Kotliar, FH Aachen, Campus Julich

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Great success of the modern keratorefractive surgery and its wide spread require high attention to the biometric parameters of the eye in pre- and post-operation period. The most important parameters are those characterizing the cornea, such as central corneal thickness and its changes, regenerative response of corneal tissue and its regulation, as well as the intraocular pressure (IOP) and its correlation with corneal parameters. Morphological structure of the cornea is altered, during various, and first of all laser surgeries with refractive, reconstructive, optical and other purposes. For the patients after corneal surgery an accurate IOP measurement without corneal contact would be desirable. The transpalpebral transscleral tonometer Diaton is small and mobile. It is a non-corneal device, which allows for IOP-measurement in sitting and supine position. recording of stationary and expansive equipment like slit lamp and air puff machines, in seated or in lying position of the patient, and it is independent from mains supply. A resent clinical study revealed that the results of IOP measurement using transpalpebral transscleral tonometry in patients with refraction anomaly before and after keratophotorefractive surgery do not depend on central corneal thickness and are similar to CCT-corrected IOP-values measured by Goldmann Applanation Tonometry. A reproducibility study with Diaton showed recently that when performed by experienced or well-trained individuals, IOPmeasurements with Diaton possess high reproducibility and low inter-grader variability. Moreover the measuring method has been shown to be easy to learn over a short time. Clinical application of transpalpebral transscleral tonometry with Diaton makes IOP-measurement efficient and economical. No additional instrumental examination, like measurement of CCT is required. This allows for the application of Diaton as a screening tonometry device both in clinical and non-clinical environment, as well as in rural areas. A particular advantage of Diaton is its ability to measure IOP in situations of contraindication to the corneal tonometry, e.g., ulcer or IOP-monitoring after keratorefractive surgery. Recent Publications: 1. A.P. Nesterov, A.R. Illarionova, B. V. Obruch(New tonometer through the eyelid TGDc-01 diaton). Vestn Oftalmol-2007, January-February; 123 (1): 42-4 2. D. Sander, A.Bohm, S. Kostov, L.Pillunat Measurement of intraocular pressure "using a tonometer through the eyelid" TGDc-01 in comparison with flatten tonometry. Graefes Arch Clin Exp Pphtalmol. 2005 June; 243 (6): 563-9 3. M.D. Dogerti, Z.I.Carr, D.P. O'Neill Diaton tonometry: estimation of the suitability and advantages in comparison with Goldmann tonometry. Clin Experiment Ophtaslmol. 2012 May-June; 40 (4): e171-5 4. J.A.Cook, A.P. Botello , A. Elders, A. Fathi Ali, A. Azuara-Blanco, K. Fraser and others Systematic review of compliance of the Goldmann tonometer to the flatten tonometry. Ophtalmology, 2012 Aug .; 119 (8): 1552-7 5. SaF04-06: Repeatability and inter observer variability of IOP data using diaton. Dashevsky A.1, Krastel H.*2, Kotliar K.3, 1Augenarztpraxis Dr. Alexej Dashevsky, MuÃ?Â?nchen, Deutschland,,2NeckargemuÃ?Â?nd, Deutschland, 3Fachhochschule Aachen, Campus JuÃ?Â?lich, Fachbereich Biomedizintechnik und Technomathematik, JuÃ?Â?lich, Deutschland. Ophthalmologe 2017 ÅE 114 (Suppl2):S7–S201, DOI 10.1007/s00347-017-0551-6.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Journal of Eye & Cataract Surgery.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Eye & Cataract Surgery
  • SubjectOphthalmology & Optometry
  • SubjectSurgery
  • BylineArticles whose byline prints “Margarita Rozhdestvenskaya”
  • BylineArticles whose byline prints “Munster”
  • BylineArticles whose byline prints “Dr. Alexey Dashevsky”
  • BylineArticles whose byline prints “Munchen”
  • BylineArticles whose byline prints “Prof. Dr.-Ing. Dr. habil. Konstantin Kotliar”
  • BylineArticles whose byline prints “FH Aachen”
  • BylineArticles whose byline prints “Campus Julich”