Research articlePublished 20 Sep 2018
Narrow and Broad Beam Attenuation of Diagnostic X Ray Beam Across Lead Sample Found in Ebonyi State, South East Nigeria
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Nigeria has over ten million tons of lead predominantly situated in the Abakaliki field in the lower benue trough. The authors decided to embark on a study to document its shielding strength towards X ray beam in the diagnostic energy range. Measurements of narrow and broad beam attenuations were made across different cut out thicknesses. Our results show that the linear attenuation coefficient is lower when compared to the value in the NIST table; 42% for N100KeV and 18% for N120KeV. These authors believe might be due to impurities because of the increased weight trying to undermine its shielding capacity or from the X ray factors. However, it could still give adequate shielding performance with a minimum thickness of 4mm following broad beam attenuation.
Subjects
Physics & AstronomyAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalResearch & Reviews: Journal of Pure and Applied Physics
- SubjectPhysics & Astronomy
- BylineArticles whose byline prints “Umeh CD”
- BylineArticles whose byline prints “Agwu KK”
- BylineArticles whose byline prints “Okoye CI”