Research article · 10 Apr 2025
Research articlePublished 2015
The Discrepancy of the Minimum Inhibitory Concentration Results for Methicillin-Resistant Staphylococcus aureus by Various Measurement Methods
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Background: It has been postulated that there exists a discrepancy of methicillin-resistant Staphylococcus aureus (MRSA) minimum inhibitory concentration (MIC) results from various measurement methods. The association between higher MRSA MIC (MIC ≥ 2 μg/ml) and worse clinical outcome has been previously reported. Therefore, it is clinically essential to investigate whether such a discrepancy exists between the different MIC measurement methods. Methods: From November 2009 to March 2011, 55 MRSA isolates were prospectively obtained at two emergency departments in Japan. The MIC of the isolates were measured by Etest® and five broth microdilution (BMD) methods, namely Eiken®, MicroScan® prompt method, MicroScan® turbidity method, Phoenix® and Vitek2® system, respectively. The MIC results of vancomycin, teicoplanin, linezolid, daptomycin and quinupristin-dalfopristin (Q-D) were evaluated. Statistical analysis was performed using the Wilcoxon signed rank test and Bland-Altman’s analysis. Results: There was a tendency of constant and significant discrepancy of MIC results of anti-MRSA antibiotics between Etest® and the BMD methods for MRSA isolates. The averages of the vancomycin MIC were 1.86 μg/ ml in Etest® and 0.74 μg/ml in the Phoenix® method (p<0.01), respectively. For teicoplanin, they were 1.86 μg/ml and 0.60 μg/ml (p<0.01), and for linezolid they were 2.55 μg/ml and 1.18 μg/ml (p<0.01) with respect to Etest® and the Phoenix® method, respectively. Among the BMD methods, however, the MicroScan® prompt method and the MicroScan® turbidity method had less discrepancy from Etest® for vancomycin MIC measurement. Conclusion: The MIC measured by various BMD methods tended to show consistently lower results compared to those measured by Etest®. Among the BMD methods, however, the MicroScan® prompt method and the MicroScan® turbidity method had less discrepancy from Etest® for vancomycin MIC measurement.
Keywords
Subjects
Anaesthesia & PainAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
More from this journal
The newest in Emergency Medicine: Open Access.
Research article · 11 Feb 2025
A Mendelian Randomization Study Investigated the Association between Socioeconomic Status and the Risk of Myocardial Infarction.
Research article · 10 Jan 2025
Awareness of Occupational Health Hazards in Prosthodontics Practices among Christian Dental Technologists in Enugu Metropolis, Nigeria
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalEmergency Medicine: Open Access
- SubjectAnaesthesia & Pain
- BylineArticles whose byline prints “Yuka Kitano”
- BylineArticles whose byline prints “Shigeki Fujitani”
- BylineArticles whose byline prints “Haruaki Wakatake”
- BylineArticles whose byline prints “Machi Yanai”
- BylineArticles whose byline prints “Sari Umekawa”
- BylineArticles whose byline prints “Yosuke Homma”
- BylineArticles whose byline prints “Yasuhiko Taira”
