Conference abstractPublished 23 Aug 2021
Early loading of immediate implant followed closed sinus lift
Suez canal university, Egypt
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Background This study evaluated the early loading of immediate implant followed trans-socket sinus lift technique Patient and methods This study was carried out on sixteen male patients received sixteen implants. Age ranged between 33-60years and the average was 42 year. After atraumatic extraction of a non- restorable maxillary premolar tooth or remaining root. The native bone distance between the planned non - restorable tooth apex and the sinus floor was less than or equal 2mm. Closed sinus lift was performed then the fixture was inserted into the socket and cover screw was secured to it. Postoperative clinical examination was done for each patient for delayed bleeding, redness, edema, swelling at surgical site, wound dehiscence, pain or implant looseness at intervals 1, after 2, 6 and 9 months postoperatively. CBCTs were done on intervals of two and nine months postoperatively to measure bone density around inserted implants and mean marginal bone loss mesially and distally. Implant stability was measured for all the implants after 2 and 9 months postoperatively by using Osstell ISQ device. Early loading of immediate implants was done after two months. All gathered data were statistically analysis by t-test. Results All patient showed normal healing with no complication was detected. After 2 months the mean and standard deviation measures of bone density around the inserted implants were (1730±178.77) while there was significant increase in bone density measurements after 9 months where the mean and standard deviation measures were (1890.52 ± 238.42). For marginal bone loss, after 2 months the mean and standard deviation were (0.74±0.11 mm) while after 9months were 0.85 ±0.16 mm. Implant stability after 2 months the mean and standard deviation measures were 68.25±2.12 while after 9 months there was significant increase in measures as the mean and standard deviation measures were 75.18±2.99. Conclusion Early loaded implant with closed sinus floor elevation is an optimizing technique to restore the function and esthetic.
Ask about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- BylineArticles whose byline prints “Ghanem Walid”