Online glutamate measurement during brain altered function with sub seconds time resolution. A new alternative to measure biological compounds with laser induced fluorescence detection and the use of enzymatic reactors
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Glutamate (Glu) constitutes the principal excitatory neurotransmitter in the brain. To understand the Glu neurotransmitter functions and their alteration in disease, methods with high temporal resolution are needed. This feature will allow correlating Glu concentrations with normal or brain altered functions. Unfortunately, available methodologies do not have the temporal resolution needed. The microdialysis technique is the most used method to measure the extracellular Glu concentrations. In this procedure, the samples are collected periodically (minutes resolution) and quantified mainly by High Performance Liquid Chromatography (HPLC). In this work, it is showed a new methodology with high temporal resolution to measure Glu. This method uses glutamate oxidase and Amplex Red, generating a fluorescent derivate (resorufin) that can be optically detected and measured. Microdialysate coming from a probe is mixed with a similar volume of an enzymatic reactor prepared to measure Glu concentration. The mixture is introduced into silica tubing placed inside of an incubation chamber at 37ºC to carry out the reaction. A fluorescence cell, located at the end of this tubing, measures fluorescence at 590 nm every two hundred milliseconds, resorufin is excited at 561 nm by a laser beam. Calibration curves were carried out immersing the probe in different Glu concentrations (50-500 uM) a linear regression analysis of 0.998 was obtained. The following experiment was carried out to validate this method. A microdialys was inserted into the hippocampus in adult awake rat. Epileptiform activity was induced administering 4-aminopyridine by reverse microdialysis procedure. Results show that abnormal electroencephalographic activity and glutamate concentrations can be correlated. These results demonstrate that this method has the appropriate sensitivity and temporal resolution to measure Glu in brain structures. This methodology could be easily adapted to measure other neurotransmitters and compounds using enzymatic reactors that generate fluorescence derivate.
Ask about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
More from this journal
The newest in Journal of Analytical & Bioanalytical Techniques.
Editorial · 29 Dec 2025
Advanced Biomarker Discovery Transforms Disease Care
Case report · 29 Dec 2025
AI Drives Advancements in Genomics and Molecular Biology
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Analytical & Bioanalytical Techniques
- SubjectBiochemistry & Biotechnology
- SubjectChemistry
- BylineArticles whose byline prints “Alberto Morales-Villagran”