Rethinking D-dimerandrsquo;s Role in the Diagnosis of Pulmonary Thromboembolism in Patients with COVID-19

Authors: Nieto Estrada Victor Hugo, Martinez Del Valle Anacaona, Valencia Moreno Albert Alexander, Molano Franco Daniel Leonardo, Calle Alvarez Elsy Sofia, Osorio Perdomo Daniela, Castaneda Ramirez Carlos Hernan, Gonzalez Zarate Natalia Andrea, Jaramillo Caceres Dayang Sulai, Bernal Salazar Tatiana Andrea

Journal of Thrombosis and Circulation: Open Access

Volume 8 · Issue 4 · Pages 1–5

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Background: D-dimer is a non-specific inflammatory marker that elevates in infections, thrombosis, and pregnancies. COVID-19 is a prothrombotic inflammatory disease, and it is common to find elevation of D-dimer in severe COVID-19 cases. The usefulness of D-dimer for the diagnosis of Pulmonary Thromboembolism (PE) in SARS CoV- 2 has not been determined. Objective: To determine the operational characteristics of D-dimer as a diagnostic method for PE in patients with COVID-19 treated at a university hospital in Bogotá, Colombia. Methods: Study of diagnostic tests that included data from patients with COVID-19 with suspected PE who were screened with the index test (D-dimer measured by turbidimetric immunoassay technique) and reference test (Angiotomography of pulmonary arteries). Results: Among the 209 patients analyzed, the prevalence of PE was 14.4%, D-dimer levels were significantly higher in the group of PE cases (2888 ng/Dl vs. 1114 ng/Dl; p=0.002). 80% of PE cases were submassive and 53% segmental. The operating characteristics for the reference cut-off point of the technique (>499 ng/mL) was Sensitivity: 93.9%, Specificity: 8.9%, Positive predictive value: 14.7%, Negative predictive value: 8.9%, proportion of false positives: 91.1% with a Youden J- index of 0.02. The area under the curve was 0.684. The coordinates of the curve showed a Youden J- index of 0.367 for a value of 2.281 ng/mL (4.5 times the reference value), using this cut-off point, we obtained a sensitivity of 60%, a specificity of 76%, PPV of 30%, NPV of 92%, and a proportion of false Negatives of 40%. Conclusion: D-dimer does not have appropriate characteristics to be used alone for the diagnosis PE in patients with severe COVID 19. It can be used as part of a rational diagnostic process, being just as specific as the patient’s signs and symptoms.

Subjects

Haematology

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Thrombosis and Circulation: Open Access
  • SubjectHaematology
  • BylineArticles whose byline prints “Nieto Estrada Victor Hugo”
  • BylineArticles whose byline prints “Martinez Del Valle Anacaona”
  • BylineArticles whose byline prints “Valencia Moreno Albert Alexander”
  • BylineArticles whose byline prints “Molano Franco Daniel Leonardo”
  • BylineArticles whose byline prints “Calle Alvarez Elsy Sofia”
  • BylineArticles whose byline prints “Osorio Perdomo Daniela”
  • BylineArticles whose byline prints “Castaneda Ramirez Carlos Hernan”
  • BylineArticles whose byline prints “Gonzalez Zarate Natalia Andrea”