A pilot-scale submerged anaerobic membrane bioreactor treating fine screened and equalized raw tannery waste water without any pretreatment was investigated in this paper to explore the biogas yield from both particulate (CODP) & soluble organic pollutants (CODS). Flat sheet anaerobic membrane with pore size of 0.4 Ã?¼m was used in this study and evaluated its performance of biogas production with Organic Loading Rate of 12 g of COD.L-1d-1. Anaerobic microbial growth in the SAMBR was measured and compared with VSS (mg.L-1) at elapsed time intervals which was further evaluated using membrane fouling characteristics by scanning electron microscope picture (SEM) of membrane, permeate velocity, CODin, CODout, COD in the reactor, biogas yield and composition of biogas, etc. The biogas generation started from the 9th day and reached the maximum by 27th day. Initially, volatile suspended solids (VSSs) and total suspended solids (TSSs) in the reactor were 4 g.L-1 and 5 g.L-1 respectively with ratio of 0.80. On the 27th day, the VSS and TSS in the SAMBR have reached a maximum value of 24 g.L-1 and 27 g.L-1 respectively with ratio of 0.89. The permeate flux was maintained at 7.06 LMH which is less than the critical flux discussed in literature and due to that fact, there was no reduction in permeate flux till the end of the experiment. Also at steady conditions, high treatment efficiency was achieved by the SAMBR with COD removal efficiency of approximately 97.14%. The methane content in the biogas was observed between 60 to 70%. High R2 value was observed between NH3 levels and alkalinity during high fouling conditions attributed to precipitation of ammonium acetate salt or struvite responsible for membrane fouling. The optimum VFA/Alkalinity ratio was 0.5, which was consistent with the peak gas yield conditions. The study recommends the removal of NH3 to avoid the membrane fouling at high OLR of 12 g of COD.L-1d-1 treating raw tannery waste water.
Subjects
Energy & PowerAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
More from this journal
The newest in Journal of Fundamentals of Renewable Energy and Applications.
Conference abstract · 17 Dec 2025
Multi-energy infrastructure for production and storage of green hydrogen
Conference abstract · 17 Dec 2025
Deforestation: the last battle against human existence
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Fundamentals of Renewable Energy and Applications
- SubjectEnergy & Power
- BylineArticles whose byline prints “Umaiyakunjaram R”
- BylineArticles whose byline prints “Shanmugam P”