Article · 26 May 2026
Research articlePublished 30 Jun 2014
study of two brands of cefuroxime 500 mg tablets (Bioxime® and Zinnat®) in adults healthy volunteers
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
A bioequivalence study of two oral formulations of Cefuroxime Axetil 500 mg Bioxime ® (Pharmacare International Manufacturing Co., Yemen) as the test and Zinnat ® (GlaxoSmithKline, UK) as the reference product was carried out in 26 healthy male & female volunteers (one drop out) following a single dose, two sequence, two period, two-treatment cross-over design. Both test and reference tablets were administered to each subject after an overnight fasting on two treatment days separated by an one-week washout period. After dosing, serial blood samples were collected for a period of 8 h. Serum harvested from blood was analyzed for Cefuroxime by a sensitive, selective, reproducible and accurate high pressure liquid chromatography (HPLC) me t h o d . Various pharmacokinetic parameters AUC0-t, AUC0-∞ , Cmax, Tmax, T1/2 and Kel were determined from Serum concentrations of both formulations and found to be in good agreement with reported values. AUC0-t, AUC0-∞, Cmax were tested for bioequivalence after log-transformation of data. No significant difference was found based on analysis of variance (ANOVA), 90% confidence interval for test/reference ratio of these parameters was found within bioequivalence acceptance range of 80-125%. Based on these statistical inferences, it was concluded that Bioxime® is bioequivalence to Zinnat®. Both products were well tolerated
Keywords
Subjects
Pharmaceutical SciencesChemistryAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
More from this journal
The newest in Journal of Chemical and Pharmaceutical Research.
Article · 12 Mar 2025
Studies on Exploring the Efficacy of Plant Based Silver Nanoparticles in Preventing Mercuric Toxicity on Blood
Article · 10 Mar 2025
Measurement of Malondialdehyde in Plasma by High Performance Liquid Chromatography Assay in Severe Cranial Trauma at The First Week of Admission: Comatose Patients
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Chemical and Pharmaceutical Research
- SubjectPharmaceutical Sciences
- SubjectChemistry
- BylineArticles whose byline prints “Sabati A. M. A”
- BylineArticles whose byline prints “Abdalwali A. Saif”
- BylineArticles whose byline prints “Mahmoud Ahmad Al Hajji”