Scholars Central

Conference abstractPublished 4 Sep 2019

Evaluation of CAD/CAM resin nano-ceramic material surface roughness and color stability after using different scaling methods

Authors: Engy Adel Ahmed Farag, Morsi T, Wahsh M, El-Etreby

British University, Egypt

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Purpose: The purpose of the study was to evaluate the effect of various scaling procedures on surface roughness and color change on a CAD/CAM resin nano-ceramic restorative material. Materials and Methods: Seventy disks (5mm diameter, 0.5mm thickness) of RNC material were cemented in standardized cavities, prepared by a specially designed reference guide in bovine teeth. The surfaces of the specimens were exposed to different scaling methods simulating standard clinical conditions, using a custommade scaling apparatus of a double pan balance. The specimens were assigned to 3 main groups: no scaling (control), ultrasonic scaling (U) and manual (M) scaling. Each group was then divided into 3 subgroups according to scaling tip material; stainless steel tip (S), plastic tip (P) and titanium tip (T). The surface texture was analyzed quantitatively and qualitatively with a profilometer and an atomic force microscopy. A spectrophotometer was used for color measurement. One-way ANOVA and Kruskal-Wallis tests were used to compare between tip materials followed by Tukey’s and Mann-Whitney tests for pair-wise comparisons. Dunnett’s test was performed to compare control group with different scaling methods. Results: Plastic curette resulted in the least surface alteration and color change. The significantly highest to lowest roughness and color change means are as follows: Control>UT>MT>US>MS>UP>MP. Deep scratches on ultrasonically scaled surfaces and numerous smaller scratches on hand-scaled surfaces were detected. The hand titanium, ultrasonic stainless steel and titanium groups were clinically unacceptable for color change. Conclusion: The use of plastic hand instrument is recommended during routine maintenance procedure for RNC materials.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Advances in Medical Research.

All its articles

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalAdvances in Medical Research
  • SubjectGeneral & Internal Medicine
  • BylineArticles whose byline prints “Engy Adel Ahmed Farag”
  • BylineArticles whose byline prints “Morsi T”
  • BylineArticles whose byline prints “Wahsh M”
  • BylineArticles whose byline prints “El-Etreby”