Scholars Central

Conference abstractPublished 4 Oct 2018

CO2 absorption studies with hybrid solvents of 1-butyl-3-methylimidazolium tetrafluoroborate (BMIM[BF4]) + N-methyl-2-pyrrolidone (NMP) using a new static-synthetic equilibrium cell

Authors: Mojgan Ebrahiminejadhasanabadi

University of KwaZulu-Natal, South Africa

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

In order to design and optimize the separation technologies based on absorption method, accurate vapour-liquid equilibrium (VLE) data obtained through reliable experimental apparatus are required. To this end, a “static-synthetic” experimental setup was designed and commissioned. The novel design of the equilibrium cell consists of a sapphire tube compressed between a bottom weld-neck (tapered) flange and a top flat stainless steel flange. The wider base allows for improved agitation of the cell contents; furthermore, the change in height of liquid can be recorded more precisely along the length of the sapphire tube with reduced diameter. An adjustable ruler was designed and attached to the cell to measure the height of liquid. The experimental method was validated by measuring the CO2 solubility in pure solvents, viz., hexane, NMP and BMIM[BF4]. Excellent agreement was obtained between the measured data and that reported in literature. New solubility data was measured for CO2 in hybrid solvents with different mass compositions (10%, 25% and 50%) of BMIM[BF4] at temperatures of 298.15, 313.15 and 323.15 K and in the pressure range of 1 to 20 bar. The viscosity, density and vapor pressure for the NMP + BMIM[BF4] mixtures were also measured. Depending on the temperature, pressure and composition of solvents, the solubility of CO2 in hybrid solvents reveals a decrease of 5% to 25% in comparison to the pure solvents. Meanwhile, the addition of NMP to BMIM[BF4], to make a mixture with 74% of ionic liquid, reduces the viscosity by approximately 70% which supports the use of BMIM[BF4] for such applications. Furthermore, the loss of solvent and its volatility were decreased when hybrid solvents were used instead of pure NMP. The experimental data were modelled using flash calculations utilizing the Peng-Robinson equation and the Wilson correlation. The average absolute relative deviations (AARD%) obtained were within 3.5%.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • BylineArticles whose byline prints “Mojgan Ebrahiminejadhasanabadi”