Scholars Central

Research articlePublished 1 Aug 2017

Hashimoto's thyroiditis shows characteristics of increased thyroid volume, decreased echo and increased blood flow signals using ultrasound gray-scale intensity technology

Authors: Yongmei Wang, Zhengmin Ruan, Junxia Zhang, Tianhua Liu, Mei Wu, Guangrui Shao

Biomedical Research

Volume 28 · Issue 14 · Pages 6365–6370

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Objective: Grey-scale intensity technology of ultrasound could test the specific quantization of grey-scale intensity of region of interest, which represented the respective characteristics of different pathological tissue changes. This study was to investigate the clinical value of grey-scale intensity quantitation analysis, also the 2D image and the distribution of blood flow by ultrasound in Hashimoto’s thyroiditis patients. Methods: A total of 55 patients with Hashimoto’s thyroiditis in our hospital from January 2012 to June 2014 were enrolled, and 50 healthy cases were enrolled as controls. LOGIQ E9 color Doppler ultrasonic diagnostic instrument (5.5-10.0 MHz) was used to examine thyroid, and the Grey-Scale Intensity of region of interest were measured. Results: There were significant differences of the size, internal echo, blood flow distribution, grey-scale intensity value between Hashimoto’s thyroiditis group and control group. The area under curve of greyscale intensity used for diagnosis of Hashimoto’s thyroiditis was 0.870. When the cut-off value of greyscale intensity used for Hashimoto’s thyroiditis diagnosis was -31.55 DB, the sensitivity was 85.5%, the specificity was 72.0% and the accuracy is 80.0%. Conclusions: The majority of Hashimoto’s thyroiditis patients had the characteristic of increased thyroid volume, decreased echo and increased blood flow signals. Grey-scale intensity quantitation analysis of ultrasound has significant differences between Hashimoto’s thyroiditis group and normal group, Grey-scale intensity quantitative analysis technology has high clinical value.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Biomedical Research.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalBiomedical Research
  • SubjectPathology & Lab Medicine
  • BylineArticles whose byline prints “Yongmei Wang”
  • BylineArticles whose byline prints “Zhengmin Ruan”
  • BylineArticles whose byline prints “Junxia Zhang”
  • BylineArticles whose byline prints “Tianhua Liu”
  • BylineArticles whose byline prints “Mei Wu”
  • BylineArticles whose byline prints “Guangrui Shao”