Conference abstract · 6 Oct 2025
Conference abstractPublished 28 Sep 2017
Agreement of fat-free mass by dual-energy x-ray absorptiometry and calculated from bioelectrical impedance equations in pre-adolescent school children (Pretoria, South Africa)
University of Pretoria, South Africa
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Reference methods for determining body composition, such as dual-energy X-ray absorptiometry (DXA) are accurate, precise and suitable for children. Th ey are however, costly, technically challenging, time-consuming and not always readily available. Bioelectrical impedance analysis (BIA) is a convenient alternative. Th e Seca medical body composition analyzer (mBCA) 515/514 has not yet been validated for prediction of body composition in children. Th e objective of the study was to determine the agreement between fat-free mass (FFM), measured by DXA and calculated from multifrequency bioelectrical impedance using published prediction equations, in pre-adolescent children. Data were collected by means of a cross-sectional study on 83 conveniently sampled African children (44 girls, 39 boys; mean (SD) age 8.5 (1.4) years). Standing height was measured with a Seca 274 stadiometer and body weight using the seca mBCA 515/514. Body composition was measured with the mBCA 515/514 and whole-body DXA scans. Diff erences between measured and calculated FFM were tested for signifi cance by paired sample t-tests. Agreement between FFM from the reference method and the individual equations was explored using the Bland-Altman method and the intra-class correlation coeffi cients. Statistically signifi cant diff erences (p<0.05) between calculated and measured FFM were observed in all but three equations. Acceptable limits of agreement were identifi ed in two of these equations. For these equations, the Bland-Altman analysis showed a mean diff erence close to zero of 0.15 (-2.683; 2.374) and 0.01 (-2.681; 2.663). Th ese two equations can be used to calculate FFM in this specifi c population using impedance values from the Seca mBCA 515/514.
Subjects
Paediatrics & NeonatologyAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
More from this journal
The newest in Pediatrics & Therapeutics.
Conference abstract · 6 Oct 2025
Out of Hospital Neonatal Outcomes (OHNO) registry
Conference abstract · 6 Oct 2025
Innovations in Early Diagnosis of Neonatal Sepsis: Advances in Biomarkers and Clinical Protocols
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalPediatrics & Therapeutics
- SubjectPaediatrics & Neonatology
- BylineArticles whose byline prints “Amanda Jansen van Rensburg”
- BylineArticles whose byline prints “White Z”
- BylineArticles whose byline prints “Wenhold F A M”
