Scholars Central

Conference abstractPublished 6 Dec 2011

Prediction of adverse perinatal outcome using antenatal umblical cord coiling index

Authors: Mohammed Azfar Siddiqui, Ibne Ahmad, Ekram Ullah, Mohd Khalid, Mehtab Ahmad, Syed Amjad Ali Rizvi

Department of Radiodiagnosis, Jawaharlal Nehru Medical College, India

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Purpose: To evaluate the abnormal antenatal umbilical cord coiling index (UCI) obtained during routine second trimester fetal anatomic survey as a predictor of adverse perinatal outcome. Method and materials: Th is prospective observational study was carried out on 150 consecutive women with uncomplicated, singleton pregnancy that had a routine second-trimester fetal morphology scan. Th e antenatal UCI was calculated as a reciprocal value of the distance between a pair of coils measured from inner edge of an arterial wall to the outer edge of the next. Th e coiling index was categorized as hypocoiled, normocoiled and hypercoiled. Th e abnormal umbilical cord coiling index was correlated with the following pregnancy outcomes: (1) small for gestational age (SFA) neonates, (2) mode of delivery, (3) presence of meconium-stained amniotic fl uid (MSAF), (4) Apgar scores at 1 minute, and (5) intrauterine deaths (IUDs). Statistical analysis was done using z- test and P-values < 0.05 was considered statistically signifi cant. Results: Out of 150 patients, only 120 patients were included in fi nal evaluation as they had all the data and adequate ultrasound images to meet the inclusion criteria. Hypercoiling was associated signifi cantly with interventional delivery (z=2.9; P< 0.05) and presence of MSAF (z=2.1; P< 0.05). Hypocoiling was associated signifi cantly with IUDs (z=3.2; P< 0.05). Hypocoiling was also associated with higher prevalence of SFA neonates, presence of MSAF, and low Apgar scores at 1 minute, but the association between them were not statistically signifi cant. Conclusion: Abnormal umbilical cord coiling index is associated with higher prevalence of interventional delivery, presence of MSAF, IUDs, SFA neonates, and low Apgar score at 1 minute. Th us abnormal umbilical cord coiling index can be used as promising prognostic marker for predicting adverse perinatal outcome. Further studies are needed to test this hypothesis.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Pediatrics & Therapeutics.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalPediatrics & Therapeutics
  • SubjectPaediatrics & Neonatology
  • BylineArticles whose byline prints “Mohammed Azfar Siddiqui”
  • BylineArticles whose byline prints “Ibne Ahmad”
  • BylineArticles whose byline prints “Ekram Ullah”
  • BylineArticles whose byline prints “Mohd Khalid”
  • BylineArticles whose byline prints “Mehtab Ahmad”
  • BylineArticles whose byline prints “Syed Amjad Ali Rizvi”