The Abbott Alinity Hq body fluid mode accurately determines low RBC concentrations in cerebrospinal fluid

Authors: Zainab Mukhtar

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Introduction: Accurately distinguishing pathological cerebrospinal fluid (CSF) from normal specimens requires manual counting of cells in a hemocytometer when WBC or RBC concentrations are low. Although WBC counts may be determined by dedicated body fluid (BF) modes on some hematology analyzers, no automated method that is currently available will be able to report RBC counts below 1,000 cells/?L. Methods: We have investigated the performance of the prototype BF mode on the Abbott Alinity Hq hematology analyzer. Data was collected on a total of 160 CSF, pleural, peritoneal and synovial fluid samples using Alinity Hq BF mode equipped with a research use, only of software version, and with the Sysmex XN-9000 BF mode in two clinical laboratories. Total nucleated cell counts (TNCC) and RBC concentrations were also determined manually using a hemocytometer. Data were analyzed after excluding duplicates, samples run in multiple dilutions, specimens with clots or cell clumps and those with missing results (e.g. as a result of insufficient sample volume). Results: There was overall good correlation between Alinity Hq and Sysmex XN-9000, TNCC and RBC were r=0.90 and 0.96, respectively, when excluding samples with RBC count of 0 (i.e. less than 1,000/?L) on the Sysmex instrument. Optimal correlation (r=1.00) was obtained between manual and both automated TNCC methods, and a slight positive bias was observed with Passing-Bablok regression (slope=1.24. and 1.11 with Alinity Hq and Sysmex XN-9000, respectively). Strong correlation was achieved between manual RBC counts and the Alinity Hq and Sysmex XN-9000 RBC counts on the 48 samples with a manual RBC concentration of >1,000/?L (r=0.97 and 0.98, and slope=1.19 and 1.05, respectively). Of the 71 samples with manual RBC count of <1,000/?L, Sysmex XN-9000 was unable to report a result in 47 cases and reported 1000 and 2000 cells/ ?L, respectively, on 19 and five of the specimens. Alinity Hq accurately quantitated RBC in these samples, achieving a correlation coefficient of 0.93, and a slope of 1.29 in comparison with the manual RBC count, and reported <10 RBC/?L in 19 samples out of the 20 with manual RBC count of <10/?L. Additionally, results were analyzed separately on the 26 CSF specimens in the cohort. TNCC counts showed a high level of correlation with the manual count (r=0.98 and 0.99 with slope=1.10 and 0.96 for Alinity Hq and Sysmex XN-9000, respectively). Sysmex XN-9000 was unable to report RBC results on all but on one CSF specimen, while Alinity Hq demonstrated a high degree of accuracy (r=1.00 and slope=1.19) when compared to the manual RBC count. Conclusion: The Alinity Hq BF mode is a promising alternative to manual cell counting in CSF and other body fluids with low cell counts.

Subjects

Haematology

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Journal of Blood Disorders & Transfusion.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Blood Disorders & Transfusion
  • SubjectHaematology
  • BylineArticles whose byline prints “Zainab Mukhtar”