Scholars Central

Conference abstract

Challenges in development and implementation of pneumatic abdominal devices in reducing craniocaudal motion of abdominal tumors for patients undergoing external beam radiation treatment/ stereotactic body radiation therapy

Authors: Kumar Deepak, Arora Deepak, An, Anil, Kaul Rakesh, Munjal R K, Patro Kartik

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Purpose: Abdominal compression is used to reduce cranio-caudal motion in abdominal cancers which helps in reduced ITVs and improved normal tissue tolerance. This advantage can help facility in introducing SBRT technique at very nominal costs. We already had been using mechanical compression devices at both locations effectively. Pneumatic devices were introduced to overcome technical limitations like assembly, ease of use, compression measurement, reproducibility etc. associated with mechanical devices. Material & Method: Pneumatic abdominal compression was made using an air bladder from blood pressure measurement instrument (Heine, German make). Position of the air bladder on abdomen was determined for its maximum efficacy. Its shape was determined by number of folds given to air bladder with or without compression plate (125x100 mm) if used. Daily reproducibility is assured by taking an impression of deflated air bladder on thermoplastic held in All In One (AIO , Orfit make) immobilization board. Pneumatic pressure is monitored through dial gauge and set in such a way that patient can feel its pressure and swallowing of breathing during simulation as well as during treatment. Under fluoroscopy reduction in CC motion is seen by observing difference in two sets of video images of diaphragm, ribs, mass or markers, one with air bladder deflated and second with air bladder inflated to known pressure. Results: 7 patients have been treated using this device at our institutes since its introduction. Mean CC motion of 18 mm (range 15-25 mm) was observed without compression and reduced mean CC motion of 10 mm (range 6-12 mm) when pneumatic compression was used. An effective reduction was observed in 90% of cases. Conclusion: Pneumatic abdominal compression device can be used effectively for reduction of CC motion in abdominal cancers radiation treatment. It can help in dose escalation due to reduced ITVs and reduced normal tissue toxicity.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Journal of Carcinogenesis & Mutagenesis.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Carcinogenesis & Mutagenesis
  • SubjectOncology & Cancer
  • BylineArticles whose byline prints “Kumar Deepak”
  • BylineArticles whose byline prints “Arora Deepak”
  • BylineArticles whose byline prints “An”
  • BylineArticles whose byline prints “Anil”
  • BylineArticles whose byline prints “Kaul Rakesh”
  • BylineArticles whose byline prints “Munjal R K”
  • BylineArticles whose byline prints “Patro Kartik”